2 papers
physics.med-ph2026
Prompt Gamma Timing for range verification with carbon ion irradiation: first experimental measurements and comparison with Geant4 Monte Carlo simulations
Iram Barbaro Rivas Ortiz, Sahar Ranjbar, Piergiorgio Cerello +14
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays…
physics.med-ph2025
Stopping power monitoring during proton therapy by means of prompt gamma timing: first experimental results with a homogeneous phantom
Julius Werner, Francesco Pennazio, Piergiorgio Cerello +11
Proton therapy's full potential is limited by uncertainties that prevent optimal dose distribution. Monitoring techniques can reduce these uncertainties and enable adaptive treatme…