A strategy to identify breakdown location in MITICA test facility: results of high voltage test campaign
Loris Zanotto, Marco Boldrin, Giuseppe Chitarin +7
The Acceleration Grid Power Supply of the MITICA test facility in Padova (Italy) is currently under commissioning. The power conversion system, the DC generator, and the High Volta…
physics.plasm-ph2023★ 12 cited
Overview on electrical issues faced during the SPIDER experimental campaigns
Alberto Maistrello, Matteo Agostini, Marco Bigi +39