13 citations · 62 across the 10 of their papers we have counts for
11 papers
Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer
Inseok Yoon
The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited suppl…
Development of novel low-mass module concepts based on MALTA monolithic pixel sensors
J Weick, F Dachs, P Riedler +13
The MALTA CMOS monolithic silicon pixel sensors has been developed in the Tower 180 nm CMOS imaging process. It includes an asynchronous readout scheme and complies with the ATLAS…
The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector
G. Abbiendi, J. Alcaraz Maestre, A. Álvarez Fernández +143
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency…
Performance of the gas gain monitoring system of the CMS RPC muon detector
L. Benussi, S. Bianco, L. Passamonti +82
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system duri…
Study of the characteristics of GEM detectors for the future FAIR experiment CBM
S. Biswas, A. Abuhoza, U. Frankenfeld +7
Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has…
CMS RPC muon detector performance with 2010-2012 LHC data
G. Pugliese
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drif…
Radiation background with the CMS RPCs at the LHC
Silvia Costantini
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of th…
Potential Impact of a New GEM-based Detector on CMS Triggering
A. Castaneda
With the increases in the LHC instantaneous luminosity, maintaining effective triggering and avoiding dead time will become especially challenging. As the sensitivity of many physi…
Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning
S. Colafranceschi, L. Benussi, S. Bianco +25
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of th…
Uniformity and Stability of the CMS RPC Detector at the LHC
S. Costantini, K. Beernaert, A. Cimmino +60
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of th…
The Upgrade of the CMS RPC System during the First LHC Long Shutdown
M. Tytgat, A. Marinov, P. Verwilligen +31
The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon…