94 citations · 160 across the 4 of their papers we have counts for
3 papers · 1 filter
The Simons Observatory: Design and Initial Performance of the Detector Readout System for the Large-Aperture Telescope
Thomas P. Satterthwaite, Tristan Pinsonneault-Marotte, Shawn W. Henderson +34
We present the design, implementation, and initial performance of a highly multiplexed cryogenic superconducting detector readout system in the context of its deployment to the Sim…
Development of readout electronics for POLARBEAR-2 Cosmic Microwave Background experiment
K. Hattori, Y. Akiba, K. Arnold +18
The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation Cosmic Microwave Background (CMB) experiment, Polarbear-2, ha…
The bolometric focal plane array of the Polarbear CMB experiment
K. Arnold, P. A. R. Ade, A. E. Anthony +53
The Polarbear Cosmic Microwave Background (CMB) polarization experiment is currently observing from the Atacama Desert in Northern Chile. It will characterize the expected B-mode p…