1.5k citations · 4.6k across the 28 of their papers we have counts for
9 papers · 1 filter
Double-beta decay of Te to the first excited state of Xe with CUORE-0
CUORE Collaboration, C. Alduino, K. Alfonso +118
We report on a search for double beta decay of Te to the first excited state of Xe using a 9.8 kgyr exposure of Te collected with the CUORE-0…
Search for Neutrinoless Decay of Te with CUORE-0
CUORE Collaboration, C. Alduino, K. Alfonso +115
We have performed a search for neutrinoless decay of Te using the final CUORE-0 data release. We describe a new analysis method for the simultaneou…
Measurement of the Two-Neutrino Double Beta Decay Half-life of Te with the CUORE-0 Experiment
CUORE Collaboration, C. Alduino, K. Alfonso +123
We report on the measurement of the two-neutrino double beta decay half-life of Te with the CUORE-0 detector. From an exposure of 33.4 kgy of TeO, the half-life…
Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in Te with CUORE-0
CUORE Collaboration, C. Alduino, K. Alfonso +118
We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta () decay in Te and the associated limit on the effective…
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
D. R. Artusa, F. T. Avignone, O. Azzolini +116
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this p…
Validation of techniques to mitigate copper surface contamination in CUORE
F. Alessandria, R. Ardito, D. R. Artusa +115
In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniqu…
CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background
F. Alessandria, E. Andreotti, R. Ardito +116
The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity…
Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay
F. Alessandria, R. Ardito, D. R. Artusa +118
We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in I…
The low-temperature energy calibration system for the CUORE bolometer array
S. Sangiorgio, L. M. Ejzak, K. M. Heeger +5
The CUORE experiment will search for neutrinoless double beta decay (0nDBD) of 130Te using an array of 988 TeO_2 bolometers operated at 10 mK in the Laboratori Nazionali del Gran S…