activity
20022026
most citedObservation of muon neutrino disappearance with the MINOS detectors and the NuMI neutrino beam

533 citations · 595 across the 20 of their papers we have counts for

collaborators

21 papers

physics.ins-det2026

Characterization and Monte Carlo Simulation of Wavelength-Shifting Absorption Length in Plastic Optical Fibers

W. Bae, L. Baker, K. Chen +11

We report an experimental characterization of the wavelength-shifting (WLS) absorption length of the EJ-160I fiber core material from Eljen Technology. Fiber-core samples of differ…

physics.ins-det2026

Optical characterization and ionizing-radiation response of the BCF-20XL scintillating fiber

W. Bae, L. Baker, K. Chen +12

We report optical characterization and ionizing-radiation measurements of the BCF-20XL scintillating fiber from Luxium Solutions, which also wavelength-shifts externally incident b…

physics.ins-det2025

Response of wavelength-shifting and scintillating-wavelength-shifting fibers to ionizing radiation

W. Bae, J. Cesar, K. Chen +23

We report results of characterizing the response and light transport of wavelength-shifting (WLS) and scintillating-wavelength-shifting (Sci-WLS) fibers under irradiation by radioa…

physics.ins-det2025

Fabrication of thin planar radiopure foils with 82Se for the SuperNEMO Demonstrator

X. Aguerre, A. Barabash, A. Basharina-Freshville +72

The SuperNEMO Demonstrator, designed to search for double beta decay using enriched 82Se, has been assembled in the Modane Underground Laboratory under the French Alps. Thin foils…

physics.ins-det2025

Optical characterization of wavelength-shifting and scintillating-wavelength-shifting fibers

W. Bae, J. Cesar, K. Chen +23

We report results of optical characterizations of new wavelength-shifting and scintillating-wavelength-shifting fibers EJ-182 and EJ-160 from Eljen Technology and compare them to t…

physics.ins-det2025

The Impact of Helium Exposure on the PMTs of the SuperNEMO Experiment

SuperNEMO Collaboration, X. Aguerre, A. S. Barabash +76

The performance of Hamamatsu 8" photomultiplier tubes (PMTs) of the type used in the SuperNEMO neutrinoless double-beta decay experiment (R5912-MOD), is investigated as a function…

physics.ins-det2024

Calorimeter commissioning of the SuperNEMO Demonstrator

X. Aguerre, A. Barabash, A. Basharina-Freshville +77

The SuperNEMO experiment is searching for neutrinoless double beta decay of \textsuperscript{82}Se, with the unique combination of a tracking detector and a segmented calorimeter.…

physics.ins-det2021

Measurement of the distribution of Bi depositions on calibration sources for SuperNEMO

R. Arnold, C. Augier, A. S. Barabash +97

The SuperNEMO experiment will search for neutrinoless double-beta decay (), and study the Standard-Model double-beta decay process (). The SuperNEMO technology can meas…

hep-ex2019★ 11 cited

EMPHATIC: A proposed experiment to measure hadron scattering and productioncross sections for improved neutrino flux predictions

T. Akaishi, L. Aliaga-Soplin, H. Asano +47

Hadron scattering and production uncertainties are a limiting systematic on accelerator and at-mospheric neutrino flux predictions. New hadron measurements are necessary for neutri…

physics.ins-det2019★ 1 cited

Spectral Characterization and Modeling of Wavelength-shifting Fibers

R. B. Pahlka, G. Elpers, J. Huang +2

We have constructed a detailed software model of photon transport in clear and wavelength shifting polystyrene optical fibers based on the GEANT4 framework. We validate the model w…

physics.ins-det2019★ 1 cited

Studies of helium poisoning of a Hamamatsu R5900-00-M16 photomultiplier

Rustem Ospanov, Michael Kordosky, Karol Lang +4

We report results from studies of the helium poisoning of a 16-anode photomultiplier tube R5900-00-M16 manufactured by Hamamatsu Photonics. A tube was immersed in pure helium for a…

physics.ins-det2016★ 6 cited

Background Studies for the MINER Coherent Neutrino Scattering Reactor Experiment

MINER Collaboration, G. Agnolet, W. Baker +47

The proposed Mitchell Institute Neutrino Experiment at Reactor (MINER) experiment at the Nuclear Science Center at Texas A&M University will search for coherent elastic neutrino-nu…

physics.ins-det2013★ 2 cited

CHerenkov detectors In mine PitS (CHIPS) Letter of Intent to FNAL

P. Adamson, S. V. Cao, J. A. B. Coelho +32

This Letter of Intent outlines a proposal to build a large, yet cost-effective, 100 kton fiducial mass water Cherenkov detector that will initially run in the NuMI beam line. The C…

hep-ex2006★ 533 cited

Observation of muon neutrino disappearance with the MINOS detectors and the NuMI neutrino beam

MINOS Collaboration

This letter reports results from the MINOS experiment based on its initial exposure to neutrinos from the Fermilab NuMI beam. The rate and energy spectra of charged current muon ne…

physics.ins-det2006★ 16 cited

Secondary Beam Monitors for the NuMI Facility at FNAL

S. Kopp, M. Bishai, M. Dierckxsens +20

The Neutrinos at the Main Injector (NuMI) facility is a conventional neutrino beam which produces muon neutrinos by focusing a beam of mesons into a long evacuated decay volume. We…

physics.ins-det2005★ 8 cited

Beam Test of a Segmented Foil SEM Grid

S. Kopp, D. Indurthy, Z. Pavlovich +8

A prototype Secondary-electron Emission Monitor (SEM) was installed in the 8 GeV proton transport line for the MiniBooNE experiment at Fermilab. The SEM is a segmented grid made wi…

physics.ins-det2005★ 2 cited

Segmented Foil SEM Grids at Fermilab

S. Kopp, D. Indurthy, Z. Pavlovich +9

We present recent beam data from a new design of a profile monitor for proton beams at Fermilab. The monitors, consisting of grids of segmented Ti foils 5micrometers thick, are sec…

physics.acc-ph2004★ 1 cited

Ion Chambers for Monitoring the NuMI Neutrino Beam at FNAL

D. Indurthy, R. Keisler, S. Kopp +15

The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense muon neutrino beam by focusing a beam of mesons into a long evacuated decay volume. The beam must be stee…

physics.ins-det2003★ 1 cited

A straw drift chamber spectrometer for studies of rare kaon decays

K. Lang, D. Ambrose, C. Arroyo +33

We describe the design, construction, readout, tests, and performance of planar drift chambers, based on 5 mm diameter copperized Mylar and Kapton straws, used in an experimental s…

hep-ex2002★ 8 cited

Beam Tests of Ionization Chambers for the NuMI Neutrino Beam

R. M. Zwaska, James Hall, Sacha E. Kopp +10

We have conducted tests at the Fermilab Booster of ionization chambers to be used as monitors of the NuMI neutrino beamline. The chambers were exposed to proton fluxes of up to 10$…

hep-ex2002★ 5 cited

The Hadron Hose: Continuous Toroidal Focusing for Conventional Neutrino Beams

J. Hylen, D. Bogert, R. Ducar +17

We have developed a new focusing system for conventional neutrino beams. The ``Hadron Hose'' is a wire located in the meson decay volume, downstream of the target and focusing horn…