activity
19952026
most citedStellar Diameters and Temperatures II. Main Sequence K & M Stars

593 citations · 5.3k across the 106 of their papers we have counts for

collaborators
Showing astro-ph.IMShow all

7 papers · 1 filter

astro-ph.IM2022★ 6 cited

CHARA/SPICA: a 6-telescope visible instrument for the CHARA Array

Denis Mourard, Philippe Berio, Cyril Pannetier +25

With a possible angular resolution down to 0.1-0.2 millisecond of arc using the 330 m baselines and the access to the 600-900 nm spectral domain, the CHARA Array is ideally configu…

astro-ph.IM2022★ 1 cited

Design of the new CHARA instrument SILMARIL: pushing the sensitivity of a 3-beam combiner in the H- and K-bands

Cyprien Lanthermann, Theo ten Brummelaar, Peter Tuthill +5

Optical interferometry is a powerful technique to achieve high angular resolution. However, its main issue is its lack of sensitivity, compared to other observation techniques. Eff…

astro-ph.IM2020★ 9 cited

CHARA Array adaptive optics: complex operational software and performance

Narsireddy Anugu, Theo ten Brummelaar, Nils H. Turner +18

The CHARA Array is the longest baseline optical interferometer in the world. Operated with natural seeing, it has delivered landmark sub-milliarcsecond results in the areas of stel…

astro-ph.IM2020★ 3 cited

CHARA/MIRC-X -- a high-sensitive six telescope interferometric imager concept, commissioning, and early science

Narsireddy Anugu, Jean-Baptiste Le Bouquin, John D. Monnier +14

MIRC-X is a six telescope beam combiner at the CHARA array that works in J and H wavelength bands and provides an angular resolution equivalent to a =331m diameter telescope. Th…

astro-ph.IM2020

A New Frontier for J-band Interferometry: Dual-band NIRInterferometry with MIRC-X

Aaron Labdon, John D. Monnier, Stefan Kraus +11

In this contribution we report on our work to increase the spectral range of the Michigan Infrared Combiner-eXeter (MIRC-X) instrument at the CHARA array to allow for dual H and J…

astro-ph.IM2020★ 1 cited

MIRC-X: a highly-sensitive six telescope interferometric imager at the CHARA Array

Narsireddy Anugu, Jean-Baptiste Le Bouquin, John D. Monnier +11

MIRC-X (Michigan InfraRed Combiner-eXeter) is a new highly-sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalen…

astro-ph.IM2010

Phase Closure Nulling: results from the 2009 campaign

Gilles Duvert, Fabien Malbet, Alain Chelli +3

We present here a new observational technique, Phase Closure Nulling (PCN), which has the potential to obtain very high contrast detection and spectroscopy of faint companions to b…