activity
20032012
most citedThe High-Acceptance Dielectron Spectrometer HADES

339 citations · 733 across the 9 of their papers we have counts for

collaborators

9 papers

physics.ins-det2012★ 37 cited

Technical Design Report for the: PANDA Micro Vertex Detector

PANDA Collaboration, W. Erni, I. Keshelashvili +454

This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as clo…

hep-ex2009★ 263 cited

Physics Performance Report for PANDA: Strong Interaction Studies with Antiprotons

PANDA Collaboration, W. Erni, I. Keshelashvili +411

To study fundamental questions of hadron and nuclear physics in interactions of antiprotons with nucleons and nuclei, the universal PANDA detector will be built. Gluonic excitation…

nucl-ex2009★ 339 cited

The High-Acceptance Dielectron Spectrometer HADES

The HADES Collaboration, G. Agakishiev, A. Balanda +110

HADES is a versatile magnetic spectrometer aimed at studying dielectron production in pion, proton and heavy-ion induced collisions. Its main features include a ring imaging gas Ch…

physics.ins-det2009★ 23 cited

Single electron response and energy resolution of a Micromegas detector

T. Zerguerras, B. Genolini, V. Lepeltier +3

Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellen…

physics.ins-det2008★ 18 cited

PMm2: large photomultipliers and innovative electronics for the next-generation neutrino experiments

B. Genolini, P. Barrillon, S. Blin +22

The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large…

physics.ins-det2008★ 42 cited

Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)

PANDA Collaboration, W. Erni, I. Keshelashvili +407

This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to m…

physics.ins-det2004★ 4 cited

The HADES Tracking System

C. Muentz

The tracking system of the dielectron spectrometer HADES at GSI Darmstadt is formed out of 24 low-mass, trapezoidal multi-layer drift chambers providing in total about 30 square me…

astro-ph2003

A Study Of Very Inclined Showers In The Pierre Auger Observatory

M. Ave

The Engineering Array of the Auger Observatory has been running successfully since 2001 and inclined showers have been recorded from the start. We have analysed the events with zen…

astro-ph2003★ 7 cited

Calibration of the Pierre Auger fluorescence detector

M. D. Roberts

The absolute calibration of an air fluorescence detector (FD) is an important element in correctly determining the energy of detected cosmic rays. The absolute calibration relates…