75 citations · 410 across the 24 of their papers we have counts for
24 papers
Tri-axial time-dependent magnetic field calibrated in-situ by harmonic analysis of adiabatically evolving atomic spins
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +1
We introduce a methodology to calibrate in situ a set of coils generating bi- or tri-axial magnetic fields, at frequencies where a calibration performed under static conditions wou…
Ion dynamic characterization using phase-resolved laser-induced fluorescence spectroscopy in a Hall effect thruster
Y. Dancheva, P. Coniglio, M. Da Valle +1
Significant information on the dynamics of the plasma constituents in Hall effect thrusters can be obtained using minimally-intrusive techniques such as laser-induced fluorescence…
Electromagnetic Induction Imaging: Signal Detection Based on Tuned-Dressed Optical Magnetometry
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +3
A recently introduced tuning-dressed scheme makes a Bell and Bloom magnetometer suited to detect weak variations of a radio-frequency (RF) magnetic field. We envisage the applicati…
Studying and applying magnetic dressing with a Bell and Bloom magnetometer
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +1
The magnetic dressing phenomenon occurs when spins precessing in a static field (holding field) are subject to an additional, strong, alternating field. It is usually studied when…
Spin dynamic response to a time dependent field
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +2
The dynamic response of a parametric system constituted by a spin precessing in a time dependent magnetic field is studied by means of a perturbative approach that unveils unexpect…
Validation of a fast and accurate magnetic tracker operating in the environmental field
Valerio Biancalana, Roberto Cecchi, Piero Chessa +4
We characterize the performance of a system based on a magnetoresistor array. This instrument is developed to map the magnetic field, and to track a dipolar magnetic source in the…
Fast, cheap, and scalable magnetic tracker with an array of magnetoresistors
Valerio Biancalana, Roberto Cecchi, Piero Chessa +3
We present the hardware of a cheap multi-sensor magnetometric setup where a relatively large set of magnetic field components is measured in several positions by calibrated magneto…
Ferromagnetic contamination of Ultra-Low-Field-NMR sample containers. Quantification of the problem and possible solutions
Giuseppe Bevilacqua, Valerio Biancalana, Marco Consumi +4
The presence of a weak remanence in Ultra-Low-Field (ULF) NMR sample containers is investigated on the basis of proton precession. The high-sensitivity magnetometer used for the NM…
Sub-millimetric ultra-low-field MRI detected in situ by a dressed atomic magnetometer
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +1
Magnetic Resonance Imaging (MRI) is universally acknowledged as an excellent tool to extract detailed spatial information with minimally invasive measurements. Efforts toward ultra…
Spurious Ferromagnetic Remanence Detected by Hybrid Magnetometer
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +2
Nuclear magnetic resonance detection in ultra low field regime enables the measurement of different components of a spurious remanence in the polymeric material constituting the sa…
Restoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +1
We study the possibility of counteracting the line-broadening of atomic magnetic resonances due to inhomogeneities of the static magnetic field by means of spatially dependent magn…
Self-adaptive loop for external disturbance reduction in differential measurement set-up
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +1
We present a method developed to actively compensate common-mode magnetic disturbances on a multi-sensor device devoted to differential measurements. The system uses a field-progra…
Simultaneous Detection of H and D NMR Signals in a micro-Tesla Field
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +3
We present NMR spectra of remote-magnetized deuterated water, detected in an unshielded environment by means of a differential atomic magnetometer. The measurements are performed i…
A low noise modular current source for stable magnetic field control
Valerio Biancalana, Giuseppe Bevilacqua, Piero Chessa +3
A low cost, stable, programmable, unipolar current source is described. The circuit is designed in view of a modular arrangement, suitable for applications where several DC sources…
Atomic orientation by a broadly frequency-modulated radiation: theory and experiment
G. Bevilacqua, V. Biancalana, Y. Dancheva
We investigate magnetic resonances driven in thermal vapour of alkali atoms by laser radiation broadly modulated at a frequency resonant with the Zeeman splitting. A model accounti…
Multichannel optical atomic magnetometer operating in unshielded environment
Giuseppe Bevilacqua, Valerio Biancalana, Piero Chessa +1
A multi-channel atomic magnetometer operating in an unshielded environment is described and characterised. The magnetometer is based on D1 optical pumping and D2 polarimetry of Cs…
Microtesla NMR J-coupling spectroscopy with an unshielded atomic magnetometer
Giuseppe Bevilacqua, Valerio Biancalana, Andrei Ben-Amar Baranga +2
We present experimental data and theoretical interpretation of NMR spectra of remotely magnetized samples, detected in an unshielded environment by means of a differential atomic m…
A fast pneumatic sample-shuttle with attenuated shocks
Valerio Biancalana, Yordanka Dancheva, Leonardo Stiaccini
We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1…
A room-temperature alternating current susceptometer - Data analysis, calibration, and test
M. Alderighi, G. Bevilacqua, V. Biancalana +3
An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magn…
Measurement of XeI and XeII velocity in the near exit plane of a low-power Hall effect thruster by light induced fluorescence spectroscopy
Y. Dancheva, V. Biancalana, D. Pagano +1
Near exit plane non-resonant light induced fluorescence spectroscopy is performed in a Hall effect low-power Xenon thruster at discharge voltage of 250V and anode flow rate of 0.7m…
Stray Magnetic Field Compensation with a Scalar Atomic Magnetometer
Jacopo Belfi, Giuseppe Bevilacqua, Valerio Biancalana +3
We describe a system for the compensation of time-dependent stray magnetic fields using a dual channel scalar magnetometer based on non-linear Faraday rotation in synchronously opt…
All-optical magnetometry for NMR detection in a micro-Tesla field and unshielded environment
Giuseppe Bevilacqua, Valerio Biancalana, Yordanka Dancheva +1
An all-optical atomic magnetometer is used to detect a proton free-precession signal from a water sample polarized in a 0.7 T field and remotely analyzed in a 4 field. Nuclear…
Dual channel self-oscillating optical magnetometer
J. Belfi, G. Bevilacqua, V. Biancalana +4
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running…
Cs CPT magnetometer for cardio-signal detection in unshielded environment
J. Belfi, G. Bevilacqua, V. Biancalana +3
We present first, encouraging results obtained with an experimental apparatus based on Coherent Population Trapping and aimed at detecting biological (cardiac) magnetic field in ma…