33 citations · 87 across the 7 of their papers we have counts for
8 papers
Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons
Javier Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco +8
Range uncertainties remain a major limitation to the full clinical exploitation of proton therapy, motivating reliable in-vivo range-verification techniques. This work presents an…
Direct Experiments of Neutron Capture on Stable and Unstable Isotopes for Stellar Nucleosynthesis Studies
Jorge Lerendegui-Marco, Javier Balibrea-Correa, Victor Babiano-Suárez +7
Neutron-capture reactions provide essential nuclear-physics input for modeling the synthesis of heavy elements in stars. The growing precision of stellar spectroscopy and isotopic…
Imaging neutrons with a position-sensitive monolithic CLYC detector
J. Lerendegui-Marco, G. Cisterna, J. Hallam +9
In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and -ray Compton scatterer of the novel dual \g-ray a…
The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy
Pablo Torres-Sánchez, Jorge Lerendegui-Marco, Javier Balibrea-Correa +12
This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in…
First Pilot Tests of Compton Imaging and Boron Concentration Measurements in BNCT Using i-TED
J. Lerendegui-Marco, J. Balibrea-Correa, P. Álvarez-Rodríguez +10
Dosimetry in BNCT poses significant challenges due to the indirect effect of neutrons interacting with elements within the body and uncertainties associated with the uptake of boro…
New detection systems for an enhanced sensitivity in key stellar (n,) measurements
J. Lerendegui-Marco, V. Babiano-Suárez, J. Balibrea-Correa +17
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in re…
Towards machine learning aided real-time range imaging in proton therapy
Jorge Lerendegui-Marco, Javier Balibrea-Correa, Víctor Babiano-Súarez +2
In this work, we report on the advantageous aspects of the i-TED Compton imager for proton-range monitoring, based on the results of the first Monte Carlo study of its applicabilit…
Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques
V. Babiano-Suárez, J. Lerendegui-Marco, J. Balibrea-Correa +132
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in () cross-section measurements using time-…