219 citations · 1.6k across the 60 of their papers we have counts for
52 papers · 1 filter
Neutral Bremsstrahlung emission in xenon unveiled
C. A. O. Henriques, P. Amedo, J. M. R. Teixeira +90
We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White TPC and a dedicated setup. Detailed comparison with first-prin…
The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers
NEXT Collaboration, B. J. P. Jones, A. Raymond +107
Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods f…
Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution
A. Simón, Y. Ifergan, A. B. Redwine +100
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any e…
Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment
NEXT Collaboration, M. Kekic, C. Adams +88
Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high energy physics. In this paper, we attempt…
Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air
S. Ghosh, J. Haefner, J. Martín-Albo +88
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a fun…
Sensitivity of a tonne-scale NEXT detector for neutrinoless double beta decay searches
NEXT Collaboration, C. Adams, V. Álvarez +96
The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification.…
Simulation results on a real-time in water tritium monitor
C. D. R. Azevedo, A. Baeza, E. Chauveau +8
In this work we present simulation results for a modular tritium in-water real-time monitor. The system allows for scalability in order to achieve the required sensitivity. The mod…
Mitigation of Backgrounds from Cosmogenic Xe in Xenon Gas Experiments using He Neutron Capture
L. Rogers, B. J. P. Jones, A. Laing +89
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutr…
Radio Frequency and DC High Voltage Breakdown of High Pressure Helium, Argon, and Xenon
K. Woodruff, J. Baeza-Rubio, D. Huerta +91
Motivated by the possibility of guiding daughter ions from double beta decay events to single-ion sensors for barium tagging, the NEXT collaboration is developing a program of R&D…
Low-diffusion Xe-He gas mixtures for rare-event detection: Electroluminescence Yield
A. F. M. Fernandes, C. A. O. Henriques, R. D. P. Mano +88
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as d…
Radiogenic backgrounds in the NEXT double beta decay experiment
NEXT Collaboration, P. Novella, B. Palmeiro +88
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced background…
Demonstration of the event identification capabilities of the NEXT-White detector
NEXT Collaboration, P. Ferrario, J. M. Benlloch-Rodríguez +88
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefor…
Energy calibration of the NEXT-White detector with 1% resolution near Q of Xe
J. Renner, G. Díaz López, P. Ferrario +87
Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta d…
TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance
C. D. R. Azevedo, A. Baeza, M. Bras +17
In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium…
Study of the loss of Xenon Scintillation in Xenon-Trimethylamine Mixtures
A. M. F. Trindade, J. Escada, A. F. V. Cortez +75
This work investigates the capability of TMA ((CH3)3N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Ligh…
Initial results on energy resolution of the NEXT-White detector
J. Renner, P. Ferrario, G. Martínez-Lema +77
One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy track…
Electroluminescence TPCs at the thermal diffusion limit
C. A. O. Henriques, C. M. B. Monteiro, D. González-Díaz +78
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the Xe isotope using a high-purity xenon TPC. Efficient discrimination of t…
Electron drift properties in high pressure gaseous xenon
NEXT Collaboration, A. Simón, R. Felkai +73
Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and diffusion is of great importance…
The Next White (NEW) detector
F. Monrabal, J. J. Gómez-Cadenas, J. F. Toledo +72
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT- White (NEW) apparatus is currently the largest high pressure xenon gas TPC using electrolu…
High Voltage Insulation and Gas Absorption of Polymers in High Pressure Argon and Xenon Gases
L. Rogers, R. A. Clark, B. J. P. Jones +3
High pressure gas time projection chambers (HPGTPCs) are made with a variety of materials, many of which have not been well characterized in high pressure noble gas environments. A…
Calibration of the NEXT-White detector using decays
G. Martínez-Lema, J. A. Hernando Morata, B. Palmeiro +74
The NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. NEXT-White has been…
Measurement of radon-induced backgrounds in the NEXT double beta decay experiment
NEXT Collaboration, P. Novella, B. Palmeiro +79
The measurement of the internal Rn activity in the NEXT-White detector during the so-called Run-II period with Xe-depleted xenon is discussed in detail, together wi…
Demonstration of Single Barium Ion Sensitivity for Neutrinoless Double Beta Decay using Single Molecule Fluorescence Imaging
A. D. McDonald, B. J. P. Jones, D. R. Nygren +71
A new method to tag the barium daughter in the double beta decay of Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dic…
Helium-Xenon mixtures to improve topological signature in high pressure gas Xenon TPCs
R. Felkai, F. Monrabal, D. Gonzalez-Díaz +72
Within the framework of xenon-based double beta decay experiments, we propose the possibility to improve the background rejection of an electroluminescent Time Projection Chamber (…