1 citations · 1 across the 2 of their papers we have counts for
3 papers
hep-ex2025
Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab
F. Abd Alrahman, P. Abratenko, N. Abrego-Martinez +194
This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, USA. The ICARUS T6…
physics.ins-det2025
Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab
Frederick Schwartz, Roberto Acciarri, Johan Bremer +9
Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi Nati…
hep-ex2023★ 1 cited
ICARUS at the Fermilab Short-Baseline Neutrino Program -- Initial Operation
ICARUS Collaboration
The ICARUS collaboration employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory studying neutrino oscillations with the CERN N…