◍wovepaper
SearchResearchersInstitutions
Sign in
researcher

T. Iwasaki

5 papers hereh-index 332 citations11 works total

Matching runs newest-first, so older work may not be attached to this profile yet.

author position
  • middle author2
  • last author3

Across the 5 of 5 papers where every author was matched, so the position is known.

fields
  • quant-ph4
  • cond-mat.supr-con1
same name
  • T. Iwasaki — 17 papers, h 33
  • T. Iwasaki — 8 papers, h 19
  • T. Iwasaki — 2 papers, h 12
  • T. Iwasaki — 2 papers, h 34
  • T. Iwasaki — 1 paper, h 11
  • T. Iwasaki — 1 paper, h 0

Either other researchers who publish under this name, or the same person where the external sources have not merged their records.

identity via Semantic Scholar / OpenAlex

activity
20232026
collaborators
Showing quant-phShow all

4 papers · 1 filter

quant-ph2026

Coherent Dark State Formation of a Lead-Vacancy Spin Qubit in Diamond

Yiyang Chen, Koyo Hirai, Tzyy Zheng Neo +7

A lead-vacancy (PbV) center in diamond exhibits coherent emission above the liquid helium temperature, making it highly attractive for quantum network applications. Here, we report…

quant-ph2026

A Highly Sensitive Diamond NV Magnetometer Using Ramsey Interferometry with a Short Sensor-to-Sample Distance

Yuta Araki, Takeharu Sekiguchi, Yuji Hatano +11

In this study, we developed a diamond quantum magnetometer based on Ramsey interferometry with a short sensor-to-sample distance. Conventional biomagnetic sensors with ensemble nit…

quant-ph2025

Multichannel highly sensitive diamond quantum magnetometer

Atsumi Yoshimura, Ayumi Kanamoto, Naota Sekiguchi +9

We demonstrate a highly sensitive real-time magnetometry method at two measurement points. This magnetometry method is based on the frequency-division multiplexing of continuous-wa…

quant-ph2023

Diamond quantum magnetometer with dc sensitivity of < 10 pT Hz−1/2 toward measurement of biomagnetic field

N. Sekiguchi, M. Fushimi, A. Yoshimura +10

We present a sensitive diamond quantum sensor with a magnetic field sensitivity of 9.4±0.1 pT/Hz​ in a near-dc frequency range of 5 to 100~Hz. This sensor is b…

◍wovepaper

Papers, researchers and institutions, woven together.

Explore
  • Search
  • Researchers
  • Institutions
Account
  • Library
  • Chat
Data
  • arXiv.org
  • Semantic Scholar
  • OpenAlex
  • Latest RSS
AboutContactPrivacyDevelopersllms.txtopenapi.json
Not affiliated with arXiv. Researcher data from Semantic Scholar (ODC-BY) and OpenAlex.