5 citations · 8 across the 4 of their papers we have counts for
4 papers · 1 filter
Test Results of PIP2IT MEBT Vacuum Protection System
A. Chen, R. Andrews, C. Baffes +4
The central part of PIP-II program of upgrades pro-posed for the Fermilab injection complex is an 800 MeV, 2 mA, CW-compatible SRF linac. Acceleration in super-conducting cavities…
Characterization of the beam from the RFQ of the PIP-II Injector Test
A. Shemyakin, J. -P. Carneiro, B. Hanna +5
A 2.1 MeV, 10 mA CW RFQ has been installed and commissioned at Fermilab's test accelerator known as PIP-II Injector Test. This report describes the measurements of the beam propert…
Installation Progress At The PIP-II Injector Test At Fermilab
C. Baffes, M. Alvarez, R. Andrews +14
A CW-compatible, pulsed H- superconducting linac "PIP-II" is being planned to upgrade Fermilab's injection complex. To validate the front-end concept, a test accelerator (The PIP-I…
Status of the warm front end of PXIE
A. Shemyakin, M. Alvarez, R. Andrews +10
A CW-compatible, pulsed H- superconducting linac is envisaged as a possible path for upgrading Fermilab's injection complex. To validate the concept of the front- end of such a mac…