43 citations · 113 across the 26 of their papers we have counts for
19 papers · 1 filter
Optimisation of TES design for the CRESST experiment
G. Angloher, S. Banik, A. Bento +54
The CRESST experiment aims at the direct detection of sub-GeV dark matter particles via elastic scattering off nuclei in different target crystals at cryogenic temperatures. The ad…
Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
M. Cappelli, A. Wallach, H. Abele +62
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of det…
ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies
G. Angloher, S. Banik, A. Bento +57
We present ImpCresst, a Geant4-based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their…
Observation of two nuclear recoil peaks induced by neutron capture on Al2O3
H. Abele, P. Ajello, B. Arnold +43
We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic AlO detector developed by the NUCLEUS collaboration for the dete…
Particle background characterization and prediction for the NUCLEUS reactor CENS experiment
H. Abele, G. Anglogher, B. Arnold +57
NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CENS) and to search for new physics at the Chooz nuclear power pl…
Description of CRESST-II and CRESST-III pulse shape data
G. Angloher, S. Banik, D. Bartolot +62
A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data…
Observation of a low energy nuclear recoil peak in the neutron calibration data of an AlO crystal in CRESST-III
CRESST Collaboration, G. Angloher, S. Banik +59
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of (10)eV for nucl…
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
H. Abele, P. Ajello, A. Armatol +51
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interes…
Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source
H. Abele, G. Angloher, B. Arnold +61
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on…
Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures
The NUCLEUS collaboration, A. Wex, J. Rothe +64
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems…
DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
G. Angloher, S. Banik, G. Benato +55
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known a…
Optimal operation of cryogenic calorimeters through deep reinforcement learning
G. Angloher, S. Banik, G. Benato +59
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In su…
Detector development for the CRESST experiment
G. Angloher, S. Banik, G. Benato +55
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment…
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
A. Erhart, V. Wagner, A. Wex +59
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon ve…
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
G. Angloher, S. Banik, G. Benato +59
Using CaWO crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identi…
Study of collision and -cascade times following neutron-capture processes in cryogenic detectors
CRAB collaboration, G. Soum-Sidikov, H. Abele +47
The emission of -rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration o…
Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
CRESST Collaboration, G. Angloher, S. Banik +58
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration…
Towards an automated data cleaning with deep learning in CRESST
G. Angloher, S. Banik, D. Bartolot +62
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a caref…
Detection System for Neutron Decay Correlations in the UCNB and Nab experiments
L. J. Broussard, B. A. Zeck, E. R. Adamek +51
We describe a detection system designed for precise measurements of angular correlations in neutron decay. The system is based on thick, large area, highly segmented silicon de…