activity
20232026
most citedDesign and simulation of a 4H-SiC low gain avalanche diode with trench-isolation

5 citations · 13 across the 10 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

7 papers · 1 filter

physics.ins-det2026

Spectacular - A Modular DAQ System for Microdosimetry

Matthias Knopf, Simon Waid, Daniel Radmanovac +8

Particle therapy using light ions like protons, helium ions or carbon ions enables precise tumor targeting with enhanced biological effectiveness while minimizing damage to healthy…

physics.ins-det2026

Measurements of the micro-spill structure of medical cyclotron and synchrotron beams and its impact on pulse pileup

Matthias Knopf, Simon Waid, Stefan Gundacker +10

Detector characterization and instrumentation testing are often performed at cyclotron and synchrotron facilities, many of which were originally developed for medical applications…

physics.ins-det2025★ 5 cited

Design and simulation of a 4H-SiC low gain avalanche diode with trench-isolation

Sebastian Onder, Philipp Gaggl, Jürgen Burin +6

We present the design and simulation of a 30 thick 4H-SiC Low Gain Avalanche Diode (LGAD) optimized for high-voltage operation. A 2.4 thick epitaxially…

physics.ins-det2025★ 2 cited

In-situ Radiation Damage Study of Silicon Carbide Detectors Subjected to Clinical Proton Beams

Daniel Radmanovac, Andreas Gsponer, Simon Waid +5

Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation sh…

physics.ins-det2025

Extraction of Electron and Hole Drift Velocities in thin 4H-SiC PIN Detectors using High-Frequency Readout Electronics

Andreas Gsponer, Sebastian Onder, Stefan Gundacker +5

Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and…

physics.ins-det2025★ 1 cited

Characterizing the Delivered Spill Structure of Medical Proton and Carbon-Ion Beams at MedAustron using a High Frequency Silicon Carbide Readout

Matthias Knopf, Andreas Gsponer, Matthias Kausel +7

Medical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, su…