567 citations · 3.9k across the 66 of their papers we have counts for
12 papers · 1 filter
Ultra-High precision Compton polarimetry at 2 GeV
A. Zec, S. Premathilake, J. C. Cornejo +13
We report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX exp…
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
ATHENA Collaboration, J. Adam, L. Adamczyk +433
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine trackin…
Accurate Determination of the Electron Spin Polarization In Magnetized Iron and Nickel Foils for Møller Polarimetry
D. C. Jones, J. Napolitano, P. A. Souder +4
The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades reaching the typica…
RTP Pockels Cell with Nanometer-Level Position Control
Caryn Palatchi, Kent Paschke
MOLLER is a future experiment designed to measure parity violation in Moller scattering to extremely high precision. MOLLER will measure the right-left scattering differential cros…
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
R. Abdul Khalek, A. Accardi, J. Adam +410
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The…
A novel comparison of Møller and Compton electron-beam polarimeters
J. A. Magee, A. Narayan, D. Jones +38
We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed…
A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab
A. Rakhman, M. Hafez, S. Nanda +13
A high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532~nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton p…
The Q_weak Experimental Apparatus
Qweak Collaboration, T. Allison, M. Anderson +126
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons fr…
Mu2e Conceptual Design Report
The Mu2e Project, Collaboration, : +225
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better…
Comparison of Modeled and Measured Performance of a GSO Crystal as Gamma Detector
D. S. Parno, M. Friend, V. Mamyan +5
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two…
The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge
R. D. Carlini, J. M. Finn, S. Kowalski +83
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and s…
Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab
M. Friend, D. Parno, F. Benmokhtar +12
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data a…