activity
19942026
most citedMeasurement of the Spin-Dependent Structure Function of the Proton

345 citations · 4.9k across the 105 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

15 papers · 1 filter

physics.ins-det2023

Long term experience with perfluorobutane in COMPASS RICH

F. Bradamante, A. Bressan, A. Cicuttin +16

COMPASS RICH-1 has used high-purity perfluorobutane as radiator gas since 2001. The operation and control of the radiator gas has evolved over years with continuous improvements. W…

physics.ins-det2020★ 3 cited

MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond

J. Agarwala, M. Alexeev, C. D. R. Azevedo +28

COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between and is provide…

physics.ins-det2019

The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1

J. Agarwala, M. Alexeev, C. D. R. Azevedo +25

After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for th…

physics.ins-det2019★ 6 cited

The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1

J. Agarwala, M. Bari, F. Bradamante +17

The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive Mic…

physics.ins-det2018★ 2 cited

Optimized MPGD-based Photon Detectors for high momentum particle identification at the Electron-Ion Collider

J. Agarwala, F. Bradamante, A. Bressan +10

Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous r…

physics.ins-det2018★ 23 cited

The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond

J. Agarwala, M. Alexeev, C. D. R. Azevedo +25

After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for th…

physics.ins-det2018

The high voltage system for the novel MPGD-based photon detectors of COMPASS RICH-1

J. Agarwala, R. Birsa, F. Bradamante +13

The architecture of the novel MPGD-based photon detectors of COMPASS RICH-1 consists in a large-size hybrid MPGD multilayer layout combining two layers of Thick-GEMs and a bulk res…

physics.ins-det2017★ 1 cited

Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors

M. Alexeev, R Birsa, F. Bradamante +31

A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m and are based on a hybrid architectu…

physics.ins-det2014★ 78 cited

The COMPASS Setup for Physics with Hadron Beams

Ph. Abbon, C. Adolph, R. Akhunzyanov +228

The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with…

physics.ins-det2012★ 37 cited

Technical Design Report for the: PANDA Micro Vertex Detector

PANDA Collaboration, W. Erni, I. Keshelashvili +454

This document illustrates the technical layout and the expected performance of the Micro Vertex Detector (MVD) of the PANDA experiment. The MVD will detect charged particles as clo…

physics.ins-det2009★ 17 cited

Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets

The PANDA Collaboration, W. Erni, I. Keshelashvili +407

This document is the Technical Design Report covering the two large spectrometer magnets of the PANDA detector set-up. It shows the conceptual design of the magnets and their antic…

physics.ins-det2009★ 13 cited

Pattern recognition and PID for COMPASS RICH-1

P. Abbon, M. Alexeev, H. Angerer +65

A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the…

physics.ins-det2008★ 42 cited

Technical Design Report for PANDA Electromagnetic Calorimeter (EMC)

PANDA Collaboration, W. Erni, I. Keshelashvili +407

This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to m…

physics.ins-det2007★ 8 cited

The Fast Read-out System for the MAPMTs of COMPASS RICH-1

C. Schill

A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-a…

physics.ins-det2006★ 12 cited

Fast Photon Detection for Particle Identification with COMPASS RICH-1

F. Nerling

Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a n…