374 citations · 525 across the 8 of their papers we have counts for
8 papers
Two-photon light-sheet live imaging at kilohertz frame rate using birefringence-based pulse splitting
Lei Zhu, Dale Gottlieb, Vincent Maioli +5
Multiphoton microscopy is widely used for live imaging. However, its acquisition speed remains limited by fluorophore emission rates and photodamage. To increase the pixel rate of…
Technical Design Report EuroGammaS proposal for the ELI-NP Gamma beam System
O. Adriani, S. Albergo, D. Alesini +106
The machine described in this document is an advanced Source of up to 20 MeV Gamma Rays based on Compton back-scattering, i.e. collision of an intense high power laser beam and a h…
High-contrast Ultrabroadband Frontend Source for High Intensity Few-Cycle Lasers
Aurélie Jullien, X. Chen, A. Ricci +7
An ultrabroadband seed source for high-power, high-contrast OPCPA systems at 800 nm is presented. The source is based on post compression in a hollow-core fiber followed by crossed…
On thermal effects in solid state lasers: the case of ytterbium-doped materials
Sebastien Chenais, Frederic Druon, Sebastien Forget +2
A review of theoretical and experimental studies of thermal effects in solid-state lasers is presented, with a special focus on diode-pumped ytterbium-doped materials. A large part…
Femtosecond laser Fourier transform absorption spectroscopy
Julien Mandon, Guy Guelachvili, Nathalie Picqué +2
A femtosecond mode-locked laser is used for the first time as a broadband infrared source for high resolution Fourier transform absorption spectroscopy. Demontration is made with a…
Passively mode-locked diode-pumped Nd:YVO4 oscillator operating at ultra-low repetition rate
Dimitris N. Papadopoulos, Sebastien Forget, M. Delaigue +3
We demonstrate the operation of an ultra low repetition rate, high peak power, picosecond diode pumped Nd:YVO4 passively mode locked laser oscillator. Repetition rates even below 1…
Direct and absolute temperature mapping and heat transfer measurements in diode-end-pumped Yb:YAG
Sebastien Chenais, Sebastien Forget, Frederic Druon +2
We report direct and absolute temperature measurements in a diode-end-pumped Yb:YAG crystal, using a calibrated infrared camera, with a 60-m spatial resolution. The heat transfe…
Passively Q-switched diode-pumped Cr4+:YAG/Nd3+:GdVO4 monolithic microchip laser
Sebastien Forget, Frederic Druon, Francois Balembois +5
the realization of high repetition rate passively Q-switched monolithic microlaser is a challenge since a decade. To achieve this goal, we report here on the first passively Q-swit…