302 citations · 1.8k across the 43 of their papers we have counts for
26 papers · 1 filter
A novel liquid argon purity monitor based on 207 Bi
B. Baibussinov, M. Bettini, F. Fabris +12
A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very pre…
Angular dependent measurement of electron-ion recombination in liquid argon for ionization calorimetry in the ICARUS liquid argon time projection chamber
ICARUS collaboration, P. Abratenko, N. Abrego-Martinez +178
This paper reports on a measurement of electron-ion recombination in liquid argon in the ICARUS liquid argon time projection chamber (LArTPC). A clear dependence of recombination o…
Study of charging-up of PCB planes for neutrino experiment readout
B. Baibussinov, M. Bettini, F. Fabris +8
The use of double-faced, metallized, perforated PCB planes, segmented into strips for the anodic read-out of ionization signals in liquid argon TPCs, is emerging as a promising tec…
Overhaul and Installation of the ICARUS-T600 Liquid Argon TPC Electronics for the FNAL Short Baseline Neutrino Program
L. Bagby, B. Baibussinov, B. Behera +61
The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016-2017 to prepare for the operation at FNAL in the Short Baseline Neutrino…
Design and implementation of the new scintillation light detection system of ICARUS T600
B. Ali-Mohammadzadeh, M. Babicz, W. Badgett +37
ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam…
Study of space charge in the ICARUS T600 detector
M. Antonello, B. Baibussinov, V. Bellini +45
The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field af…
Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector
M. Babicz, L. Bagby, B. Baibussinov +35
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster…
New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system
L. Bagby, B. Baibussinov, V. Bellini +42
The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included al…
Operation of a LAr-TPC equipped with a multilayer LEM charge readout
B. Baibussinov, S. Centro, C. Farnese +8
A novel detector for the ionization signal in a single phase LAr-TPC, based on the adoption of a multilayer Large Electron Multiplier (LEM) replacing the traditional anodic wire ar…
The Single-Phase ProtoDUNE Technical Design Report
B. Abi, R. Acciarri, M. A. Acero +824
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a cr…
Muon momentum measurement in ICARUS-T600 LAr-TPC via multiple scattering in few-GeV range
Maddalena Antonello, Bagdat Baibussinov, Vincenzo Bellini +54
The measurement of muon momentum by Multiple Coulomb Scattering is a crucial ingredient to the reconstruction of νμ CC events in the ICARUS-T600 liquid argon TPC in absence of magn…
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 1: The LBNF and DUNE Projects
R. Acciarri, M. A. Acero, M. Adamowski +795
This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline…
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report, Volume 4 The DUNE Detectors at LBNF
R. Acciarri, M. A. Acero, M. Adamowski +795
A description of the proposed detector(s) for DUNE at LBNF
Operation and performance of the ICARUS-T600 cryogenic plant at Gran Sasso underground Laboratory
M. Antonello, P. Aprili, B. Baibussinov +55
ICARUS T600 liquid argon time projection chamber is the first large mass electronic detector of a new generation able to combine the imaging capabilities of the old bubble chambers…
A Proposal for a Three Detector Short-Baseline Neutrino Oscillation Program in the Fermilab Booster Neutrino Beam
R. Acciarri, C. Adams, R. An +221
A Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab is presented. This new SBN Program will deliver…
Experimental observation of an extremely high electron lifetime with the ICARUS-T600 LAr-TPC
M. Antonello, B. Baibussinov, P. Benetti +54
The ICARUS T600 detector, the largest liquid Argon Time Projection Chamber (LAr-TPC) realized after many years of RD activities, was installed and successfully operated for 3 years…
The trigger system of the ICARUS experiment for the CNGS beam
M. Antonello, B. Baibussinov, P. Benetti +56
The ICARUS T600 detector, with its 470 tons of active mass, is the largest liquid Argon TPC ever built. Operated for three years in the LNGS underground laboratory, it has collecte…
ICARUS at FNAL
M. Antonello, B. Baibussinov, V. Bellini +63
The INFN and the ICARUS collaboration originally developed the technology of the LAr-TPC. Located the underground LNGS Hall-B, the ICARUS T600 detector has been performed over thre…
Precise 3D track reconstruction algorithm for the ICARUS T600 liquid argon time projection chamber detector
M. Antonello, B. Baibussinov, P. Benetti +53
Liquid Argon Time Projection Chamber (LAr TPC) detectors offer charged particle imaging capability with remarkable spatial resolution. Precise event reconstruction procedures are c…
Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN
M. Antonello, D. Bagliani, B. Baibussinov +136
A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by…
Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors
M. Antonello, D. Bagliani, B. Baibussinov +136
This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's…
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
R. Acciarri, M. Antonello, F. Boffelli +26
Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scatt…
The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature
B. Baibussinov, C. Carpanese, F. Casagrande +11
We describe characteristics and performance of the low-noise front-end preamplifier used in the ICARUS 50-litre liquid Argon Time Projection Chamber installed in the CERN West Area…
A hardware implementation of Region-of-Interest selection in LAr-TPC for data reduction and triggering
B. Baibussinov, S. Centro, K. Cieslik +11
Large Liquid Argon TPC detectors in the range of multikton mass for neutrino and astroparticle physics require the extraction and treatment of signals from some 105 wires. In order…