activity
20242026
most citedPICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

2 citations · 2 across the 12 of their papers we have counts for

collaborators

13 papers

hep-ex2026

Construction, commissioning, and performance of the ENUBET demonstrator

F. Acerbi, I. Angelis, L. Bomben +75

A final full-size prototype of the instrumented decay tunnel of ENUBET, referred to as the Demonstrator, was constructed and its performance was tested during the 2022, 2023 and 20…

physics.ins-det2026

Optical readout of MPGDs with solid wavelength shifters

F. M. Brunbauer, A. Cools, M. Cortesi +20

Optical readout of MicroPattern Gaseous Detectors (MPGDs) makes use of the high granularity of imaging sensors to achieve good spatial resolution for radiation imaging and particle…

physics.ins-det2026

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with active area

A. Pandey, K. Gnanvo, B. Kross +60

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and…

physics.ins-det2026

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

M. Lisowska, F. Guerra, A. Gurpinar +46

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targe…

physics.ins-det2026

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

F. M. Brunbauer, R. Aleksan, Y. Angelis +47

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolu…

physics.ins-det2025

Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector

Djunes Janssens, Antonija Utrobicic, Marinko Kovacic +52

The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a…

physics.ins-det2025

μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector

Kondo Gnanvo

The PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to p…

physics.ins-det2025

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

A. Kallitsopoulou, S. Aune, Y. Angelis +54

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micr…

physics.ins-det2025

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

A. Kallitsopoulou, R. Aleksan, S. Aune +49

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and ph…

hep-ex2025

nuSCOPE: A short-baseline neutrino beam at CERN for high-precision cross-section measurements

F. Acerbi, C. Andreopoulos, I. Angelis +81

A new generation of neutrino cross-section experiments at the GeV scale is crucial in the precision era of oscillation physics and lepton flavor studies. In this document, we prese…

physics.ins-det2025

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

Y. Meng, R. Aleksan, Y. Angelis +49

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector…

hep-ex2025

The ENUBET monitored neutrino beam and its implementation at CERN

ENUBET collaboration, L. Halić, F. Acerbi +74

The ENUBET project recently concluded the R&D for a site independent design of a monitored neutrino beam for high precision cross section measurements, in which the neutrino flux i…

physics.ins-det2024★ 2 cited

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

A. Kallitsopoulou, R. Aleksan, Y. Angelis +49

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged…