2 citations · 2 across the 12 of their papers we have counts for
13 papers
Construction, commissioning, and performance of the ENUBET demonstrator
F. Acerbi, I. Angelis, L. Bomben +75
A final full-size prototype of the instrumented decay tunnel of ENUBET, referred to as the Demonstrator, was constructed and its performance was tested during the 2022, 2023 and 20…
Optical readout of MPGDs with solid wavelength shifters
F. M. Brunbauer, A. Cools, M. Cortesi +20
Optical readout of MicroPattern Gaseous Detectors (MPGDs) makes use of the high granularity of imaging sensors to achieve good spatial resolution for radiation imaging and particle…
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with active area
A. Pandey, K. Gnanvo, B. Kross +60
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and…
Advances in photocathode development for PICOSEC Micromegas precise-timing detectors
M. Lisowska, F. Guerra, A. Gurpinar +46
The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targe…
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
F. M. Brunbauer, R. Aleksan, Y. Angelis +47
The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolu…
Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector
Djunes Janssens, Antonija Utrobicic, Marinko Kovacic +52
The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a…
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Kondo Gnanvo
The PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to p…
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
A. Kallitsopoulou, S. Aune, Y. Angelis +54
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micr…
Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors
A. Kallitsopoulou, R. Aleksan, S. Aune +49
We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and ph…
nuSCOPE: A short-baseline neutrino beam at CERN for high-precision cross-section measurements
F. Acerbi, C. Andreopoulos, I. Angelis +81
A new generation of neutrino cross-section experiments at the GeV scale is crucial in the precision era of oscillation physics and lepton flavor studies. In this document, we prese…
PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration
Y. Meng, R. Aleksan, Y. Angelis +49
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector…
The ENUBET monitored neutrino beam and its implementation at CERN
ENUBET collaboration, L. Halić, F. Acerbi +74
The ENUBET project recently concluded the R&D for a site independent design of a monitored neutrino beam for high precision cross section measurements, in which the neutrino flux i…
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
A. Kallitsopoulou, R. Aleksan, Y. Angelis +49
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged…