24 citations · 45 across the 17 of their papers we have counts for
12 papers · 1 filter
Advances in photocathode development for PICOSEC Micromegas precise-timing detectors
M. Lisowska, F. Guerra, A. Gurpinar +46
The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targe…
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
F. M. Brunbauer, R. Aleksan, Y. Angelis +47
The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolu…
Test-beam results from MiniCACTUS-v2: A depleted monolithic CMOS timing sensor prototype
Y. Degerli, R. Aleksan, R. Casanova +9
MiniCACTUS-v2 is a monolithic sensor prototype designed in LF 150 nm CMOS process for time tagging of individual Minimum Ionizing Particles with an accuracy better than 100 ps. The…
Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector
Djunes Janssens, Antonija Utrobicic, Marinko Kovacic +52
The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a…
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Kondo Gnanvo
The PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to p…
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
A. Kallitsopoulou, S. Aune, Y. Angelis +54
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micr…
Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors
A. Kallitsopoulou, R. Aleksan, S. Aune +49
We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and ph…
PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration
Y. Meng, R. Aleksan, Y. Angelis +49
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector…
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
A. Kallitsopoulou, R. Aleksan, Y. Angelis +49
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged…
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
X. Wang, R. Aleksan, Y. Angelis +48
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes eq…
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
M. Lisowska, R. Aleksan, Y. Angelis +55
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structur…
Single channel PICOSEC Micromegas detector with improved time resolution
A. Utrobicic, R. Aleksan, Y. Angelis +47
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses th…