activity
20032022
most citedObservation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

193 citations · 943 across the 21 of their papers we have counts for

collaborators

23 papers

hep-ex2022★ 1 cited

Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora

DUNE Collaboration, A. Abed Abud, B. Abi +1220

The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time project…

hep-ex2022★ 1 cited

A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

A. Abed Abud, B. Abi, R. Acciarri +1239

This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector.…

hep-ex2022★ 7 cited

Snowmass Neutrino Frontier: DUNE Physics Summary

DUNE Collaboration, A. Abed Abud, B. Abi +1240

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrin…

physics.ins-det2022★ 11 cited

Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network

DUNE Collaboration, A. Abed Abud, B. Abi +1221

Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the techn…

physics.ins-det2021★ 1 cited

Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC

DUNE Collaboration, A. Abed Abud, B. Abi +1175

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. Th…

hep-ex2021

Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

DUNE Collaboration, A. Abed Abud, B. Abi +1151

The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's se…

hep-ex2021

Searching for solar KDAR with DUNE

DUNE Collaboration, A. Abed Abud, B. Abi +1174

The observation of 236 MeV muon neutrinos from kaon-decay-at-rest (KDAR) originating in the core of the Sun would provide a unique signature of dark matter annihilation. Since exce…

physics.ins-det2021★ 10 cited

The EXO-200 detector, part II: Auxiliary Systems

N. Ackerman, J. Albert, M. Auger +157

The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…

physics.ins-det2021★ 2 cited

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

R. Linehan, R. L. Mannino, A. Fan +46

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless do…

physics.ins-det2021

Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report

A. Abed Abud, B. Abi, R. Acciarri +1059

This report describes the conceptual design of the DUNE near detector

physics.ins-det2020★ 60 cited

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…

physics.ins-det2018★ 77 cited

nEXO Pre-Conceptual Design Report

nEXO Collaboration, S. Al Kharusi, A. Alamre +171

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…

physics.ins-det2017

LUX-ZEPLIN (LZ) Technical Design Report

B. J. Mount, S. Hans, R. Rosero +259

In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achi…

physics.ins-det2012★ 153 cited

The EXO-200 detector, part I: Detector design and construction

M. Auger, D. J. Auty, P. S. Barbeau +78

EXO-200 is an experiment designed to search for double beta decay of Xe with a single-phase, liquid xenon detector. It uses an active mass of 110 kg of xenon enriched to 80…

physics.ins-det2011★ 19 cited

Xenon purity analysis for EXO-200 via mass spectrometry

A. Dobi, C. Hall, S. Slutsky +73

We describe purity measurements of the natural and enriched xenon stockpiles used by the EXO-200 double beta decay experiment based on a mass spectrometry technique. The sensitivit…

nucl-ex2011★ 193 cited

Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200

N. Ackerman, B. Aharmim, M. Auger +100

We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Stand…

physics.ins-det2011★ 19 cited

A magnetically-driven piston pump for ultra-clean applications

F. LePort, R. Neilson, P. S. Barbeau +77

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the r…

physics.ins-det2009★ 56 cited

Characterization of large area APDs for the EXO-200 detector

R. Neilson, F. LePort, A. Pocar +49

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurem…

physics.ins-det2007★ 150 cited

Systematic study of trace radioactive impurities in candidate construction materials for EXO-200

D. S. Leonard, P. Grinberg, P. Weber +54

The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a…

physics.ins-det2007★ 27 cited

A linear RFQ ion trap for the Enriched Xenon Observatory

B. Flatt, M. Green, J. Wodin +39

The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the…

physics.ins-det2006★ 8 cited

A liquid xenon ionization chamber in an all-fluoropolymer vessel

EXO Collaboration, F. LePort, A. Pocar +42

A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low ra…

cond-mat.other2005★ 11 cited

Mobility of thorium ions in liquid xenon

K. Wamba, C. Hall, M. Breidenbach +27

We present a measurement of the Th ion mobility in LXe at 163.0 K and 0.9 bar. The result obtained, 0.2400.011 (stat) 0.011 (syst) cm/(kV-s), is compared wi…

hep-ex2003★ 137 cited

Correlated Fluctuations between Luminescence and Ionization in Liquid Xenon

E. Conti, R. DeVoe, G. Gratta +19

The ionization of liquefied noble gases by radiation is known to be accompanied by fluctuations much larger than predicted by Poisson statistics. We have studied the fluctuations o…