activity
20232026
most citedThe i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy

9 citations · 17 across the 8 of their papers we have counts for

collaborators
Showing 2024Show all

5 papers · 1 filter

physics.ins-det2024

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

J. Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco +134

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn,…

physics.ins-det2024★ 1 cited

Towards Real Time Compton Imaging in Demanding Conditions

Bernardo Gameiro, Jorge Lerendegui-Marco, Victor Babiano-Suarez +5

Compton cameras are radiation detectors that provide spatial information on the origin of the γ-ray sources based on the Compton scattering effect. Many applications require these…

physics.ins-det2024★ 2 cited

Imaging neutrons with a position-sensitive monolithic CLYC detector

J. Lerendegui-Marco, G. Cisterna, J. Hallam +9

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and -ray Compton scatterer of the novel dual \g-ray a…

physics.med-ph2024★ 9 cited

The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy

Pablo Torres-Sánchez, Jorge Lerendegui-Marco, Javier Balibrea-Correa +12

This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in…

physics.med-ph2024★ 3 cited

First Pilot Tests of Compton Imaging and Boron Concentration Measurements in BNCT Using i-TED

J. Lerendegui-Marco, J. Balibrea-Correa, P. Álvarez-Rodríguez +10

Dosimetry in BNCT poses significant challenges due to the indirect effect of neutrons interacting with elements within the body and uncertainties associated with the uptake of boro…