84 citations · 704 across the 43 of their papers we have counts for
11 papers · 1 filter
Characterisation of the neutron beam in the n_TOF-EAR2 experimental area at CERN following the spallation target upgrade
J. A. Pavon-Rodriguez, J. Lerendegui-Marco, A. Manna +16
The n_TOF facility at CERN has undergone a major upgrade after the installation of a new spallation target, designed to improve the features of both neutron beamlines at the experi…
Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams
J. Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco +134
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn,…
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
J. Balibrea Correa, J. Lerendegui-Marco, V. Babiano-Suarez +131
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterizat…
Commissioning of miniBELEN-10A, a moderated neutron counter with a flat efficiency for thick-target neutron yields measurements
N Mont-Geli, A Tarifeño-Saldivia, L M Fraile +40
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (…
miniBELEN: a modular neutron counter for (alpha,n) reactions
N Mont-Geli, A Tarifeño-Saldivia, L M Fraile +38
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reasse…
The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements
N. Patronis, A. Mengoni, N. Colonna +130
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized b…
Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques
V. Babiano-Suárez, J. Lerendegui-Marco, J. Balibrea-Correa +132
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in () cross-section measurements using time-…
Review and new concepts for neutron-capture measurements of astrophysical interest
C. Domingo-Pardo, V. Babiano-Suarez, J. Balibrea-Correa +128
The idea of slow-neutron capture nucleosynthesis formulated in 1957 triggered a tremendous experimental effort in different laboratories worldwide to measure the relevant nuclear p…
Experimental setup and procedure for the measurement of the 7Be(n,p)7Li reaction at n_TOF
M. Barbagallo, J. Andrzejewski, M. Mastromarco +125
Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned a…
GEANT4 simulation of the neutron background of the CD set-up for capture studies at n_TOF
TOF collaboration, P. Žugec, N. Colonna +104
The neutron sensitivity of the CD detector setup used at n_TOF for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software repli…
A new CVD Diamond Mosaic-Detector for (n,) Cross-Section Measurements at the n\_TOF Experiment at CERN
C. Weiss, E. Griesmayer, C. Guerrero +1
At the n\_TOF experiment at CERN a dedicated single-crystal chemical vapor deposition (sCVD) Diamond Mosaic-Detector has been developed for (n,) cross-section measurements. The…