Studies of CPT symmetry in positronium decays with 192 plastic strip J-PET detector
N. Chug, S. D. Bass, E. Y. Beyene +40
A direct test of the CPT symmetry is performed for the electromagnetic decays of ortho-positronium using the J-PET tomograph. We present the precise measurement of the CPT-sensitiv…
Nanoporosity imaging by positronium lifetime tomography
K. Dulski, E. Beyene, N. Chug +25
Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the…
Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study
M. Dadgar, S. Parzych, F. Tayefi Ardebili +29
The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-ba…
Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner
L. Kaplon, J. Baran, N. Chug +31
Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpo…
Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner
P. Moskal, D. Kumar, S. Sharma +25
In state-of-the-art Positron Emission Tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintil…
Feasibility studies for imaging ee annihilation with modular multi-strip detectors
S. Sharma, L. Povolo, S. Mariazzi +41
Studies based on imaging the annihilation of the electron (e) and its antiparticle positron (e) open up several interesting applications in nuclear medicine and fundame…
Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators
Meysam Dadgar, Szymon Parzych, Jakub Baran +28
Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and…
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
R. Y. Shopa, J. Baran, K. Klimaszewski +32
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (T…
J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams
S. Sharma, J. Baran, R. S. Brusa +33
The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 p…