60 citations · 393 across the 56 of their papers we have counts for
58 papers
Effects of energy spread on Brightness and Coherence of undulator sources
Gianluca Geloni, Svitozar Serkez, Ruslan Khubbutdinov +2
The (spectral) brightness for partially transverse coherent sources as Synchrotron Radiation (SR) and Free-Electron Laser (FEL) sources can be defined as the maximum of the Wigner…
Relativity and Accelerator Engineering
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
From a geometrical viewpoint, according to the theory of relativity, space and time constitute a four-dimensional continuum with pseudo-Euclidean structure. This has recently begun…
On Radiation Emission from a Microbunched Beam with Wavefront Tilt and Its Experimental Observation
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
In this paper we compare experimental observations and theory of radiation emission from a microbunched beam with microbunching wavefront tilt with respect to the direction of moti…
Opportunities for Two-color Experiments at the SASE3 undulator line of the European XFEL
Gianluca Geloni, Vitali Kocharyan, Tommaso Mazza +3
X-ray Free Electron Lasers (XFELs) have been proven to generate short and powerful radiation pulses allowing for a wide class of novel experiments. If an XFEL facility supports the…
Radiation by Moving Charges
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
It is generally accepted that the dynamics of relativistic particles in the lab frame can be described by taking into account the relativistic dependence of the particles momenta o…
On the Coupling of Fields and Particles in Accelerator and Plasma Physics
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
In accelerator and plasma physics it is accepted that there is no need to solve the dynamical equations for particles in covariant form, i.e. by using the coordinate-independent pr…
Circular polarization opportunities at the SASE3 undulator line of the European XFEL
Svitozar Serkez, Gianluca Geloni, Vitali Kocharyan +1
XFELs provide X-ray pulses with unprecedented peak brightness and ultrashort duration. They are usually driven by planar undulators, meaning that the output radiation is linearly p…
Evidence of Wigner Rotation Phenomena in the Beam Splitting Experiment at the LCLS
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
A result from particle tracking states that, after a microbunched electron beam is kicked, its trajectory changes while the orientation of the microbunching wavefront remains as be…
A Critical Experimental Test of Synchrotron Radiation Theory with 3rd Generation Light Source
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
A recent "beam splitting" experiment at LCLS apparently demonstrated that after a microbunched electron beam is kicked on a large angle compared to the divergence of the FEL radiat…
Misconception Regarding Conventional Coupling of Fields and Particles in XFEL Codes
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
Maxwell theory is usually treated in the lab frame under the standard time order (light-signal clock synchronization). Particle tracking in the lab frame usually treats time as an…
Modulated Electron Bunch with Amplitude Front Tilt in an Undulator
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
In a previous paper we discussed the physics of a microbunched electron beam kicked by the dipole field of a corrector magnet by describing the kinematics of coherent undulator rad…
Effect of Aberration of Light in X-ray Free Electron Lasers
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
We discuss the physics of a microbunched electron beam kicked by the dipole field of a corrector magnet by describing the kinematics of coherent undulator radiation after the kick.…
Scheme to increase the output average spectral flux of the European XFEL at keV
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
Techniques like inelastic X-ray scattering (IXS) and nuclear resonance scattering (NRS) are currently limited by the photon flux available at X-ray sources. At keV, third ge…
Novel opportunities for sub-meV inelastic X-ray scattering at high-repetition rate self-seeded X-ray free-electron lasers
Oleg Chubar, Gianluca Geloni, Vitali Kocharyan +5
Inelastic X-ray scattering (IXS) is an important tool for studies of equilibrium dynamics in condensed matter. A new spectrometer recently proposed for ultra-high-resolution IXS (U…
Theoretical computation of the polarization characteristics of an X-ray Free-Electron Laser with planar undulator
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
We show that radiation pulses from an X-ray Free-Electron Laser (XFEL) with a planar undulator, which are mainly polarized in the horizontal direction, exhibit a suppression of the…
Brightness of synchrotron radiation from wigglers
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
According to literature, while calculating the brightness of synchrotron radiation from wigglers, one needs to account for the so called `depth-of-field' effects. In fact, the part…
Perspectives of Imaging of Single Protein Molecules with the Present Design of the European XFEL. - Part I - X-ray Source, Beamlime Optics and Instrument Simulations
Svitozar Serkez, Vitali Kocharyan, Evgeni Saldin +3
The Single Particles, Clusters and Biomolecules (SPB) instrument at the European XFEL is located behind the SASE1 undulator, and aims to support imaging and structure determination…
Brightness of Synchrotron radiation from Undulators and Bending Magnets
Gianluca Geloni, Vitali Kocharyan, Evgeni Saldin
We consider the maximum of the Wigner distribution (WD) of synchrotron radiation (SR) fields as a possible definition of SR source brightness. Such figure of merit was originally i…
The Full Potential of the Baseline SASE Undulators of the European XFEL
Ilya Agapov, Gianluca Geloni, Guangyao Feng +4
The output SASE characteristics of the baseline European XFEL, recently used in the TDRs of scientific instruments and X-ray optics, have been previously optimized assuming uniform…
Nonlinear undulator tapering in conventional SASE regime at baseline electron beam parameters as a way to optimize the radiation characteristics of the European XFEL
Svitozar Serkez, Vitali Kocharyan, Evgeni Saldin +2
We demonstrate that the output radiation characteristics of the European XFEL sources at nominal operation point can be easily made significantly better than what is currently repo…
Proposal to generate 10 TW level femtosecond x-ray pulses from a baseline undulator in conventional SASE regime at the European XFEL
Svitozar Serkez, Vitali Kocharyan, Evgeni Saldin +2
Output characteristics of the European XFEL have been previously studied assuming an operation point at 5 kA peak current. In this paper we explore the possibility to go well beyon…
Purified SASE undulator configuration to enhance the performance of the soft x-ray beamline at the European XFEL
Svitozar Serkez, Vitali Kocharyan, Evgeni Saldin +2
The purified SASE (pSASE) undulator configuration recently proposed at SLAC promises an increase in the output spectral density of XFELs. In this article we study a straightforward…
Extension of SASE bandwidth up to 2% as a way to increase the efficiency of protein structure determination by x-ray nanocrystallography at the European XFEL
Svitozar Serkez, Vitali Kocharyan, Evgeni Saldin +3
Femtosecond x-ray nanocrystallography exploiting XFEL radiation is an emerging method for protein structure determination using crystals with sizes ranging from a few tens to a few…
Proposal for a scheme to generate 10 TW-level femtosecond x-ray pulses for imaging single protein molecules at the European XFEL
Svitozar Serkez, Vitali Kocharyan, Evgeni Saldin +3
Single biomolecular imaging using XFEL radiation is an emerging method for protein structure determination using the "diffraction before destruction" method at near atomic resoluti…