5 citations · 24 across the 22 of their papers we have counts for
22 papers
Does Global seismic energy release increase? An analysis based on the Lithospheric Seismic Energy Flow Model (LSEFM). The case of mega - earthquakes (M > 9)
C. Thanassoulas, V. Klentos, G. Verveniotis +1
In this work the data of the earthquake catalog of the NOAA, National Geophysical Data Center (NGDC) are processed in terms of global seismic energy release. The determined Global…
Preseismic electric signals generated by critical stress loading of the lithosphere. A review of the type of signals obtained from a long lasted (1999 to 2012) experiment conducted in Greece
C. Thanassoulas, V. Klentos, G. Verveniotis +1
In this work a review is made of the various preseismic electric signals that have been observed before large EQs in Greece during the period of 1999 to 2012. The observed preseism…
Was the magnitude (M = 9.0R) of the mega-earthquake of Japan (11th of March, 2011) predictable? An analysis based on the Lithospheric Seismic Energy Flow Model (LSEFM)
C. Thanassoulas, V. Klentos, G. Verveniotis
The Tohoku EQ (11th of March, 2011, M = 9.0) in Japan falsified the proposed EQ magnitude range (M = 7.0 - 8.5) of the same seismogenic regional area that had been determined by th…
Do large EQs occur randomly in time? The Mexico EQ (20th of March, 2012, Mw = 7.4) as viewed in terms of local lithospheric oscillation due to M1 and K1 tidal components. A brief presentation
C. Thanassoulas, V. Klenvas, G. Verveniotis +1
The time of occurrence of the large EQ that occurred recently in Mexico (March 20th, 2012, Mw = 7.4) is compared to the peak amplitude occurrence time of the local M1 and K1 tidal…
The Earth's oscillating electric field (T = 1 day) in relation to the occurrence time of large EQs (Ms>5.0R). A postulated theoretical physical working model and its statistical validation
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The mechanically oscillating, due to tidal forces, lithosperic plate activates, because of its high content in quartzite, the generation of a piezoelectric field. Due to the same m…
Can large (M >= 8) EQs be triggered by tidal (M1) waves? An analysis of the global seismicity that occurred during 1901 - 2011
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The analysis of two global data sets of large earthquakes (2010 - 2011, 30 samples of M \geq 7R and 1901-2011, 178 samples of M \geq 8R) reveals that there exists a cause and effec…
On the recent large EQ of Karpathos, Greece (April 1st, 2011, Ms = 6.7R) and its similarities to the large EQ of the January 1st, 2006 (Ms = 6.9R) at East of Kythira, Greece
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The recent large EQ that occurred in Greece (April 1st, 2011, Ms = 6.7R) is investigated as far as it concerns regional geophysical features of the Greek territory. In particular,…
The Japan earthquake of March 11th, 2011 (Mw = 8.9R) as viewed in terms of local lithospheric oscillation due to M1 and K1 tidal components. A brief presentation
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The time of occurrence of the large EQ that occurred recently in Japan (March 11th, 2011, Mw = 8.9) is compared to the time of peak amplitude occurrence of the M1 and K1 tidal comp…
A short note on the two most recent large EQs of New Zealand (Mw=7.0 on September 3rd, 2010 and Mw=6.1 on February 21st, 2011). A typical example of tidally triggered large EQs by the M1 tidal component
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The time of occurrence of the two most resent large EQs of New Zealand (Mw = 7.0 on September 3rd, 2010 and Mw = 6.1 on February 21st, 2011) is compared to the time when the lithos…
The background seismicity rate of the Greek territory, considered as a unified seismogenic area, for the period 1964 - 2010. Is Greece in course for a large seismic event?
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The analysis of the earthquakes catalog of Greece for the period 1964 to 2010 indicates a continuously increasing no. of seismic events. A detailed determination of the cumulative…
The Andravida, Greece EQ (8/06/2008, Ms=7.0R). An "a posteriori" analysis for the determination of its location, occurrence time and magnitude parameters in terms of short-term predictability
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The Andravida EQ, Greece (8/6/2008, Ms=7.0R) seismic parameters: location, time of occurrence and magnitude were determined "a posteriori" in an attempt to verify the predictabilit…
Amplitude modulated, by M1, Earth's oscillating (T = 1 day) electric field triggered by K1 tidal waves. Its relation to the occurrence time of large EQs
C. Thanassoulas, V. Klentos, G. Verveniotis
Starting from the observation that quite often the Earth's oscillating electric field varies in amplitude, a mechanism is postulated that accounts for these observations. That mech…
"Strange attractor like" electric seismic precursor observed prior to the Nafpactos, Greece, EQs of 18th / 22nd January, 2010 (Ms = 5.7R / 5.6R)
C. Thanassoulas, V. Klentos, G. Verveniotis
Phase maps, of the earth's electric field monitored at PYR and ATH monitoring sites in Greece, were compiled for two distinct oscillating earth's electric field components long bef…
Medium - long term earthquake prediction by the use of the oscillating electric field (T = 365 days) generated due to Earth's orbit around the Sun and due to its consequent oscillating lithospheric deformation
C. Thanassoulas, V. Klentos, P. Tsailas +2
We study the Earth's electric field monitored at PYR (Greece) monitoring site, for a period of more than six years (May 23rd, 2003 to September 7th, 2009). It is compared, in parti…
Seismic electric precursors observed prior to the 6.3R EQ of July 1st 2009, Greece and their use in short-term earthquake prediction
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The normalized raw data of the Earth's electric field, monitored at PYR, ATH, HIO monitoring sites in Greece, are studied as far as it concerns the presence of electric seismic pre…
Decomposing the "strange attractor like" seismic electric precursor into simpler components
C. Thanassoulas, V. Klentos, G. Verveniotis +1
An attempt is made in this work to decompose the "strange attractor like" seismic electric precursor into more simple and elementary components. The basic data files of the orthogo…
Preseismic oscillating electric field "strange attractor like" precursor, of T = 6 months, triggered by Ssa tidal wave. Application on large (Ms > 6.0R) EQs in Greece (October 1st, 2006 - December 2nd, 2008)
C. Thanassoulas, V. Klentos, G. Verveniotis +1
In this work the preseismic "strange attractor like" precursor is studied, in the domain of the Earth's oscillating electric field for T = 6 months. It is assumed that the specific…
Preseismic oscillating electric field "strange attractor" like precursor, of T=14 days, triggered by M1 tidal wave. Application on large (Ms > 6.0R) EQs in Greece (March 18th, 2006 - November 17th, 2008)
C. Thanassoulas, V. Klentos, G. Verveniotis +1
The "strange attractor like" precursor, calculated from the Earth's oscillating electric field registered at PYR and HIO monitoring sites located in Greece, is studied in the domai…
Preseismic electric field "strange attractor" like precursor analysis applied on large (Ms > 5.5R) EQs, which occurred in Greece during December 1st, 2007 - April 30th, 2008
C. Thanassoulas, V. Klentos, G. Verveniotis +1
In order to investigate the capability of the preseismic electric field "strange attractor like" precursor as a time predictor of a large EQ within a short time window (short-term…
On a preseismic electric field "strange attractor" like precursor observed short before large earthquakes
C. Thanassoulas, V. Klentos, G. Verveniotis
The Earth's electric field, recorded by two different and distant monitoring sites located in Greece, is analyzed in terms of monochromatic signals (T=24h). The analysis is based o…
Multidirectional analysis of the oscillating (T = 24 hours) Earth's electric field recorded on ground surface
C. Thanassoulas, V. Klentos, G. Verveniotis
The Earth's preseismic oscillating (T = 24h) electric field recorded for a short-time period of some days is analyzed in terms of its intensity vector azimuthal direction calculate…
Extracting preseismic electric signals from noisy Earth's electric field data recordings. The "noise injection" method
C. Thanassoulas, V. Klentos, G. Verveniotis
An entirely different approach is used for the extraction of preseismic electric signals from highly contaminated by noise data series. The basic element of this method is the "Dir…