Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
N. Schermer, H. Abele, G. Angloher +57
The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CENS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this wo…
Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
M. Cappelli, A. Wallach, H. Abele +62
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of det…
Characterization of the Low Energy Excess using a NUCLEUS AlO detector
H. Abele, G. Angloher, B. Arnold +62
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other…
Observation of two nuclear recoil peaks induced by neutron capture on Al2O3
H. Abele, P. Ajello, B. Arnold +43
We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic AlO detector developed by the NUCLEUS collaboration for the dete…
Particle background characterization and prediction for the NUCLEUS reactor CENS experiment
H. Abele, G. Anglogher, B. Arnold +57
NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CENS) and to search for new physics at the Chooz nuclear power pl…
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
H. Abele, P. Ajello, A. Armatol +51
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interes…
Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source
H. Abele, G. Angloher, B. Arnold +61
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on…
Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures
The NUCLEUS collaboration, A. Wex, J. Rothe +64
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems…
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
A. Erhart, V. Wagner, A. Wex +59
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon ve…
Study of collision and -cascade times following neutron-capture processes in cryogenic detectors
CRAB collaboration, G. Soum-Sidikov, H. Abele +47
The emission of -rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration o…
Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment
The NUCLEUS collaboration, C. Goupy, H. Abele +59
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS…
Development of a compact muon veto for the NUCLEUS experiment
V. Wagner, R. Rogly, A. Erhart +52
The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e.,…
Calibration of nuclear recoils at the 100 eV scale using neutron capture
L. Thulliez, D. Lhuillier, F. Cappella +34
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy…