5 citations · 9 across the 8 of their papers we have counts for
9 papers
Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
N. Schermer, H. Abele, G. Angloher +57
The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CENS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this wo…
Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
M. Cappelli, A. Wallach, H. Abele +62
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of det…
Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches
H. Abele, G. Angloher, B. Arnold +62
The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CENS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters…
Observation of two nuclear recoil peaks induced by neutron capture on Al2O3
H. Abele, P. Ajello, B. Arnold +43
We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic AlO detector developed by the NUCLEUS collaboration for the dete…
Commissioning of the NUCLEUS Experiment at the Technical University of Munich
H. Abele, G. Angloher, B. Arnold +57
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO targets in the fully coherent regime, using gram-scale cryog…
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
H. Abele, P. Ajello, A. Armatol +51
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interes…
Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source
H. Abele, G. Angloher, B. Arnold +61
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on…
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
A. Erhart, V. Wagner, A. Wex +59
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon ve…
Calibration of nuclear recoils at the 100 eV scale using neutron capture
L. Thulliez, D. Lhuillier, F. Cappella +34
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy…