317 citations · 337 across the 8 of their papers we have counts for
9 papers
A Hydrogenated Amorphous Silicon Photodiode indirect flexible device for radiation flux measurements at low intensities
Mauro Menichelli, Aishah Bashiri, Marco Bizzarri +46
The objective of the Photo-HASPIDE experiment is the construction and test of an indirect a-Si:H (Hydrogenated Amorphous Silicon) photo-detector plus scintillator device on a flexi…
Proton irradiation on Hydrogenated Amorphous Silicon flexible devices
M. Menichelli, S. Aziz, A. Bashiri +58
Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displa…
Characterization of hydrogenated amorphous silicon sensors on polyimide flexible substrate
M. Menichelli, L. Antognini, S. Aziz +50
Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these propert…
A Hydrogenated amorphous silicon detector for Space Weather Applications
Catia Grimani, Michele Fabi, Federico Sabbatini +35
The characteristics of a hydrogenated amorphous silicon (a-Si:H) detector are presented here for monitoring in space solar flares and the evolution of large energetic proton events…
Development of thin hydrogenated amorphous silicon detectors on a flexible substrate
M. Menichelli, M. Bizzarri, L. Calcagnile +40
The HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project aims at the development of thin hydrogenated amorphous silicon (a-Si:H) detectors on flexible substrates (most…
Testing of planar hydrogenated amorphous silicon sensors with charge selective contacts for the construction of 3D- detectors
M. Menichelli, M. Bizzarri, M. Boscardin +29
Hydrogenated Amorphous Silicon (a-Si:H) is a material well known for its intrinsic radiation hardness and is primarily utilized in solar cells as well as for particle detection and…
Quantification of pulmonary involvement in COVID-19 pneumonia by means of a cascade oftwo U-nets: training and assessment on multipledatasets using different annotation criteria
Francesca Lizzi, Abramo Agosti, Francesca Brero +11
The automatic assignment of a severity score to the CT scans of patients affected by COVID-19 pneumonia could reduce the workload in radiology departments. This study aims at explo…
A new measurement of direct CP violation in two pion decays of the neutral kaon
The NA48 Collaboration, V. Fanti
The NA48 experiment at CERN has performed a new measurement of direct CP violation, based on data taken in 1997 by simultaneously collecting K_L and K_S decays into pi0pi0 and pi+p…
Status report of the NA48 experiment at the CERN SPS
Cinzia Talamonti
The aim of the NA48 experiment at the CERN SPS is to measure direct CP violation in neutral kaon decays thus determining the parameter with an accuracy of .…