activity
20132021
most citedTransverse beam size measurement system using visible synchrotron radiation at HLS II

10 citations · 17 across the 7 of their papers we have counts for

collaborators

7 papers

physics.ins-det2021

Hefei light source storage ring bunch by bunch 3D position measuring system is introduced and a preliminary study is shown

Ping Lu, Leilei Tang, Baogen Sun +4

The 4 electrode signals of the beam position detector(BPM) of the STORAGE ring of HEFEI Light Source are directly connected to the domestic oscilloscope with 12bit resolution, 10Gs…

physics.acc-ph2017★ 4 cited

The bunch current measurement using high-speed photodetector at HLS II

Tian-Yu Zhou, Yong-Liang Yang, Bao-Gen Sun +7

This contribution presents a novel bunch current measurement system based on an ultra-fast photodetector and a high-speed digitizer at Hefei Light Source II (HLS II). In order to a…

physics.acc-ph2016★ 10 cited

Transverse beam size measurement system using visible synchrotron radiation at HLS II

Kai Tang, Bao-Gen Sun, Yong-Liang Yang +6

An interferometer system and an imaging system using visible synchrotron radiation (SR) have been installed in HLS II storage ring. Simulations of these two systems are given using…

physics.acc-ph2015★ 1 cited

Central frequency measurement of the HLS-II storage ring

Jiajun Zheng, Yongliang Yang, Baogen Sun +3

Central frequency is a key parameter of storage rings. This paper presents the measurement of central frequency of the HLS-II storage ring using the sextupole modulation method. Fi…

physics.acc-ph2015★ 2 cited

Beam size and position measurement based on logarithm processing algorithm in HLS II

Chaocai Cheng, Baogen Sun, Yongliang Yang +9

A logarithm processing algorithm to measure beam transverse size and position is proposed and preliminary experimental results in Hefei Light Source II (HLS II) are given. The algo…

physics.acc-ph2013

A new measurement method of electrode gains for orthogonal symmetric type beam position monitor

J. Y. Zou, F. F Wu, Y. L. Yang +5

The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four ortho…

physics.acc-ph2013

A waveguide overloaded cavity kicker for the HLS II longitudinal feedback system

Wubin Li, Zeran Zhou, Baogen Sun +4

In the upgrade project of Hefei Light Source (HLS II), a new digital longitudinal bunch-by-bunch feedback system will be developed to suppress the coupled bunch instabilities in th…