11 citations · 32 across the 11 of their papers we have counts for
11 papers
Performance study of a bakelite RPC prototype built by new technique of linseed oil coating
A. Sen, S. Mandal, S. Chatterjee +3
Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreate…
Investigation of the stability in the performance of triple GEM detectors for High Energy Physics experiments
S. Mandal, S. Chatterjee, A. Sen +6
Gas Electron Multiplier (GEM) is one of the mostly used gaseous detectors in the High Energy Physics (HEP) experiments. GEMs are widely used as tracking devices due to their high-r…
Observation on the bias current variation of a single mask triple GEM chamber
S. Chatterjee, A. Sen, R. Paul +3
Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The hig…
Effect of charging-up on the uniformity of a single mask triple GEM detector
S. Chatterjee, A. Sen, S. Das +1
The Gas Electron Multiplier (GEM) detector is one of the advanced members of the Micro Pattern Gas Detector (MPGD) family, used in High Energy Physics (HEP) experiments as a tracki…
Visual investigation of possible degradation in GEM foil under test
S. Chatterjee, A. Sen, S. Das +1
Visual investigation of a Single Mask (SM) Gas Electron Multiplier (GEM) foil, showing small resistance~( 40 k), is performed manually using an optical microscope. The GEM…
Effect of relative humidity on the long-term operation of a single mask triple GEM chamber
S. Chatterjee, A. Sen, S. Das +1
The characteristic studies of a Single Mask~(SM) triple Gas Electron Multiplier (GEM) detector are carried out using Ar/CO gas mixture in 70/30 volume ratio in continuous flow…
Commissioning and testing of pre-series triple GEM prototypes for CBM-MuCh in the mCBM experiment at the SIS18 facility of GSI
A. Kumar, A. Agarwal, S. Chatterjee +25
Large area triple GEM chambers will be employed in the first two stations of the MuCh system of the CBM experiment at the upcoming Facility for Antiproton and Ion Research FAIR in…
Study of charging-up effect for a single mask triple GEM detector
S. Chatterjee, A. Sen, S. Das +2
With the advancement of the accelerator systems and the requirements of high luminosity particle beams to reach different physics goals, detectors with good position resolution and…
Spark probability measurement of a single mask triple GEM detector
S. Chatterjee, U. Frankenfeld, C. Garabatos +6
Triple Gas Electron Multiplier (GEM) detectors will be used as a tracking device in the first two stations of CBM MUon CHamber (MUCH), where the maximum particle rate is expected t…
Development and implementation of a time-based signal generation scheme for the Muon Chamber simulation of the CBM experiment at FAIR
V. Singhal, S. Chatterjee, V. Friese +1
The Compressed Baryonic Matter~(CBM) experiment in the upcoming Facility for Antiproton and Ion Research~(FAIR), designed to take data in nuclear collisions at very high interactio…
Characterisation of an RPC prototype with moderate resistivity plates using tetrafluoroethane ()
Arindam Sen, Sayak Chatterjee, Shreya Roy +2
Keeping in mind the requirements of high rate capable, cost effective, large area detectors to be used in future high energy physics experiments, commercially available bakelite pl…