most citedFeasibility study of the positronium imaging with the J-PET tomograph

142 citations · 256 across the 8 of their papers we have counts for

collaborators

9 papers

physics.med-ph2026

Three-Photon Bayesian Imaging of Ortho-Positronium

L. Raczynski, W. Krzemien, A. Coussat +5

PET provides functional images relying on two-photon coincidences from positron-electron annihilation. In human tissue, about 40\% of annihilations are preceded by Ps formation, of…

cs.CV2026

A systematic evaluation of machine learning classifiers for event-by-event background rejection in LAFOV PET scanners

Konrad Klimaszewski, Michał Obara, Mateusz Bala +5

The introduction of LAFOV PET scanners brings significant sensitivity gains but also a substantial increase in the background rate from accidental coincidences, phantom-scattered a…

hep-ph2026

Ortho-Positronium Three-Photon Decays: Physics Constraints and a Closed-Form Energy Method for Annihilation Vertex Reconstruction

L. Raczyński, W. Krzemień, A. Coussat +5

We examine the physical foundations of orthopositronium three-photon decay in the context of annihilation vertex reconstruction, focusing on how energy-momentum conservation constr…

physics.med-ph2026

A Monte Carlo positronium decay source model with multiple annihilation channels in GATE

Wojciech Krzemien, Mateusz Bala, Kamil Dulski +7

Positronium-based imaging requires realistic modelling of positronium (Ps) decay in matter. We introduce a modular Ps decay model implemented in GATE 9.4 and GATE 10, enabling the…

physics.med-ph2023

Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

Meysam Dadgar, Szymon Parzych, Jakub Baran +28

Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and…

physics.ins-det2023★ 6 cited

J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

S. Sharma, J. Baran, R. S. Brusa +33

The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 p…

physics.med-ph2022★ 2 cited

Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Jakub Baran, Wojciech Krzemien, Lech Raczyński +31

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods…

nucl-ex2021★ 106 cited

Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

Paweł Moskal, Aleksander Gajos, Muhsin Mohammed +35

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discr…

physics.ins-det2018★ 142 cited

Feasibility study of the positronium imaging with the J-PET tomograph

P. Moskal, D. Kisielewska, C. Curceanu +27

A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the densi…