activity
20132024
most citedQED Meson Description of the X17 and Other Anomalous Particles

46 citations · 101 across the 7 of their papers we have counts for

collaborators

7 papers

nucl-ex2024★ 1 cited

Search for the X17 particle in processes with the MEG II detector

The MEG II collaboration, K. Afanaciev, A. M. Baldini +64

The observation of a resonance structure in the opening angle of the electron-positron pairs in the Li(p,\ee) Be reaction was claimed and interpreted as the production…

physics.ins-det2023★ 2 cited

Performances of a new generation tracking detector: the MEG II cylindrical drfit chamber

A. M. Baldini, H. Benmansour, G. Boca +28

The cylindrical drift chamber is the most innovative part of the MEG~II detector, the upgraded version of the MEG experiment. The MEG~II chamber differs from the MEG one because it…

hep-ph2022★ 46 cited

QED Meson Description of the X17 and Other Anomalous Particles

Cheuk-Yin Wong

The X17 particle, the E38 particle, and the anomalous soft photons are anomalous particles because they do not appear to belong to any known Standard Model families. We propose a Q…

physics.ins-det2020★ 12 cited

Performance of an optically read out time projection chamber with ultra-relativistic electrons

V. C. Antochi, E. Baracchini, L. Benussi +28

The Time Projection Chamber (TPC) is an ideal candidate to finely study the charged particle ionization in a gaseous medium. Large volumes TPCs can be read out with a suitable numb…

physics.ins-det2018★ 27 cited

Combined readout of a triple-GEM detector

Vasile C. Antochi, Elisabetta Baracchini, Gianluca Cavoto +7

Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order o…

physics.ins-det2015★ 5 cited

Polycrystalline para-terphenyl scintillator adopted in a detecting probe for radio-guided surgery

Elena Solfaroli Camillocci, Fabio Bellini, Valerio Bocci +15

A radio-guided surgery technique exploiting emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical…

physics.med-ph2013★ 8 cited

Extended calibration range for prompt photon emission in ion beam irradiation

F. Bellini, T. T. Boehlen, M. P. W. Chin +18

Monitoring the dose delivered during proton and carbon ion therapy is still a matter of research. Among the possible solutions, several exploit the measurement of the single photon…