5 citations · 13 across the 14 of their papers we have counts for
17 papers
Optical readout of MPGDs with solid wavelength shifters
F. M. Brunbauer, A. Cools, M. Cortesi +20
Optical readout of MicroPattern Gaseous Detectors (MPGDs) makes use of the high granularity of imaging sensors to achieve good spatial resolution for radiation imaging and particle…
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with active area
A. Pandey, K. Gnanvo, B. Kross +60
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and…
Advances in photocathode development for PICOSEC Micromegas precise-timing detectors
M. Lisowska, F. Guerra, A. Gurpinar +46
The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targe…
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
F. M. Brunbauer, R. Aleksan, Y. Angelis +47
The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolu…
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Kondo Gnanvo
The PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to p…
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
A. Kallitsopoulou, S. Aune, Y. Angelis +54
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micr…
Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors
A. Kallitsopoulou, R. Aleksan, S. Aune +49
We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and ph…
Measurements of enriched 155 Gd and 157Gd converters with the NMX detector on the nTOF EAR2 beam line at CERN
D. Pfeiffer, F. M. Brunbauer, I. R. Fehse +15
The detectors for the NMX instrument at the European Spallation Source (ESS) in Lund use natural Gd as the neutron converter. In 2024, beam time was obtained at the neutron time-of…
Embedding the Timepix4 in Micro-Pattern Gaseous Detectors
L. Scharenberg, J. Alozy, W. Billereau +27
The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous…
The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout
F. Garcia, K. J. Flöthner, A. Amato +21
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in differen…
Towards MPGDs with embedded pixel ASICs
L. Scharenberg, J. Alozy, W. Billereau +27
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution…
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
A. Kallitsopoulou, R. Aleksan, Y. Angelis +49
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged…
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
X. Wang, R. Aleksan, Y. Angelis +48
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes eq…
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
M. Lisowska, R. Aleksan, Y. Angelis +55
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structur…
Optical Readout Studies of the Thick-COBRA Gaseous Detector
F. Garcia, F. M. Brunbauer, M. Lisowska +11
The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its ope…
Nanodiamond photocathodes for MPGD-based single photon detectors at future EIC
F. M. Brunbauer, C. Chatterjee, G. Cicala +17
We are developing gaseous photon detectors for Cherenkov imaging applications in the experiments at the future Electron Ion Collider. CsI, converting photons in the far ultraviolet…
Nanodiamond photocathodes for MPGD-based single photon detectors at future EIC
C. Chatterjee, G. Cicala, A. Cicuttin +12
The design of a Ring Imaging CHerenkov (RICH) detector for the identification of high momentum particles at the future Electron Ion Collider (EIC) is extremely challenging by using…