187 citations · 201 across the 8 of their papers we have counts for
9 papers
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with active area
A. Pandey, K. Gnanvo, B. Kross +60
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and…
Advances in photocathode development for PICOSEC Micromegas precise-timing detectors
M. Lisowska, F. Guerra, A. Gurpinar +46
The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targe…
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
F. M. Brunbauer, R. Aleksan, Y. Angelis +47
The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolu…
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Kondo Gnanvo
The PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to p…
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
A. Kallitsopoulou, S. Aune, Y. Angelis +54
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micr…
Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors
A. Kallitsopoulou, R. Aleksan, S. Aune +49
We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and ph…
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
I. Manthos, S. Aune, J. Bortfeldt +41
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the…
Timing performance of a multi-pad PICOSEC-Micromegas detector prototype
S. Aune, J. Bortfeldt, F. Brunbauer +39
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a…
JUNO Conceptual Design Report
T. Adam, F. An, G. An +347
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km awa…