7 citations · 24 across the 17 of their papers we have counts for
10 papers · 1 filter
The Magnetic-Resonance-Based, Omni-Directional Hydrophone
Nathan Thyberg, Davi Cavinatto, Katia Oler +3
This study aims to improve the directional sensitivity of magnetic resonance hydrophone (MRH) methods and allow for detection and quantification of waves traveling at any angle rel…
Light-sheet microscopy to assess cancer pathology: current views and future trends
Uma Pisarović, Taichi Ochi, Iryna Samarska +6
In recent years, light-sheet fluorescence microscopy (LSFM) has emerged as a powerful tool for visualizing and analyzing cancer tissue samples, including patient-derived specimens,…
Preclinical Water-Mediated Ultrasound Platform using Clinical FOV for Molecular Targeted Contrast-Enhanced Ultrasound
Stavros Melemenidis, Anna Stephanie Kim, Jenny Vo-Phamhi +3
Background: This protocol introduces an ultrasound (US) configuration for whole-body 3D dynamic contrast-enhanced ultrasound (DCE-US) imaging in preclinical applications. The set-u…
A novel imaging setup for hybrid radiotherapy tailored PET/MR in patients with head and neck cancer
R. M. Winter, O. Engelsen, O. J. Bratting +4
Purpose: Radiotherapy commonly relies on CT, but there is growing interest in using hybrid PET/MR. Therefore, dedicated hardware setups have been proposed for PET/MR systems which…
Rosette spectroscopic imaging for whole-brain metabolite mapping at 7T: acceleration potential and reproducibility
Zhiwei Huang, Uzay Emir, Andre Doring +4
Whole-brain proton magnetic resonance spectroscopic imaging (1H-MRSI) is a non-invasive technique for assessing neurochemical distribution in the brain, offering valuable insights…
The effects of intra-detector Compton scatter on zero-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors
Fredrik Grönberg, Zhye Yin, Jonathan Maltz +2
Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significan…
Hessian filter-assisted full diameter at half maximum (FDHM) segmentation and quantification method for optical-resolution photoacoustic microscopy
Dong Zhang, Ran Li, Xin Lou +1
Optical-resolution photoacoustic microscopy has been validated as a high-resolution and high-sensitivity imaging modality for angiographic studies in the past decades. Quantitative…
A Deep Learning Model with Radiomics Analysis Integration for Glioblastoma Post-Resection Survival Prediction
Zongsheng Hu, Zhenyu Yang, Haozhao Zhang +4
Purpose: To develop a novel deep-learning model that integrates radiomics analysis in a multi-dimensional feature fusion workflow for glioblastoma (GBM) post-resection survival pre…
Role of AI in Theranostics: Towards Routine Personalized Radiopharmaceutical Therapies
Julia Brosch-Lenz, Fereshteh Yousefirizi, Katherine Zukotynski +5
We highlight emerging uses of artificial intelligence (AI) in the field of theranostics, focusing on its significant potential to enable routine and reliable personalization of rad…
Optimized application of double and single layer BEM for in vivo conductivity estimation
Jan C de Munck, Andreas Daffertshofer, Victoria Montes-Restrepo +3
Inter subject variability of the electrical conductivity of brain, skull and skin strongly limits the accuracy by which current sources underlying electro-encephalography (EEG) can…