activity
20122026
most citedExchange-dependent relaxation in the rotating frame for slow and intermediate exchange - modeling off-resonant spin-lock and chemical exchange saturation transfer

221 citations · 424 across the 19 of their papers we have counts for

collaborators
Showing physics.med-phShow all

14 papers · 1 filter

physics.med-ph2026

Agentic Autoresearch for CT Reconstruction

Andreas Maier, Lucas Kachelriess, Siming Bayer +4

Comparing CT reconstruction methods fairly is labor-intensive and largely manual, and many benchmarks use idealized data. We ask whether a large language model (LLM) agent can do t…

physics.med-ph2026

MR Simulation with Phase Distribution Graphs: Off-Resonant Pulse Response and Slice-Selection

Felix Dietz, Jonathan Endres, Simon Weinmueller +2

Purpose: Phase Distribution Graphs were introduced as a powerful tool for on-resonant MRI simulations. Herein, we extend the concept beyond the assumptions of hard and on-resonant…

physics.med-ph2024

MR-zero meets FLASH -- Controlling the transient signal decay in gradient- and rf-spoiled gradient echo sequences

Simon Weinmüller, Jonathan Endres, Nam Dang +2

Abstract Purpose The complex signal decay during the transient FLASH MRI readout can lead to artifacts in magnitude and phase images. We show that target-driven optimization of ind…

physics.med-ph2024

Enhanced and Robust Contrast in CEST MRI: Saturation Pulse Shape Design via Optimal Control

Clemens Stilianu, Christina Graf, Markus Huemer +5

Purpose: To employ optimal control for the numerical design of CEST saturation pulses to maximize contrast and stability against inhomogeneities. Theory and Methods: We appli…

physics.med-ph2024

MR sequence design to account for non-ideal gradient performance

Daniel J West, Felix Glang, Jonathan Endres +4

MRI systems are traditionally engineered to produce close to idealized performance, enabling a simplified pulse sequence design philosophy. An example of this is control of eddy cu…

physics.med-ph2023

Joint MR sequence optimization beats pure neural network approaches for spin-echo MRI super-resolution

Hoai Nam Dang, Vladimir Golkov, Thomas Wimmer +3

Current MRI super-resolution (SR) methods only use existing contrasts acquired from typical clinical sequences as input for the neural network (NN). In turbo spin echo sequences (T…

physics.med-ph2022★ 27 cited

Accelerated and Quantitative 3D Semisolid MT/CEST Imaging using a Generative Adversarial Network (GAN-CEST)

Jonah Weigand-Whittier, Maria Sedykh, Kai Herz +7

Purpose: To substantially shorten the acquisition time required for quantitative 3D chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) imaging a…

physics.med-ph2022

snapshot CEST++ : the next snapshot CEST for fast whole-brain APTw imaging at 3T

Patrick Liebig, Maria Sedykh, Kai Herz +6

CEST suffers from two main problems long acquisitin times or restricted coverage as well as incoherent protocol settings. In this paper we give suggestions on how to optimise your…

physics.med-ph2021★ 55 cited

An End-to-End AI-Based Framework for Automated Discovery of CEST/MT MR Fingerprinting Acquisition Protocols and Quantitative Deep Reconstruction (AutoCEST)

Or Perlman, Bo Zhu, Moritz Zaiss +2

Purpose: To develop an automated machine-learning-based method for the discovery of rapid and quantitative chemical exchange saturation transfer (CEST) MR fingerprinting acquisitio…

physics.med-ph2020★ 58 cited

MRzero -- Fully automated discovery of MRI sequences using supervised learning

Alexander Loktyushin, Kai Herz, Nam Dang +7

Purpose: A supervised learning framework is proposed to automatically generate MR sequences and corresponding reconstruction based on the target contrast of interest. Combined with…

physics.med-ph2019★ 58 cited

CEST MR-Fingerprinting: practical considerations and insights for acquisition schedule design and improved reconstruction

Or Perlman, Kai Herz, Moritz Zaiss +3

Purpose: To understand the influence of various acquisition parameters on the ability of CEST MR-Fingerprinting (MRF) to discriminate different chemical exchange parameters and to…

physics.med-ph2018★ 1 cited

DeepCEST: 9.4 T Chemical Exchange Saturation Transfer MRI contrast predicted from 3 T data - a proof of concept study

Moritz Zaiss, Anagha Deshmane, Mark Schuppert +6

Purpose: Separation of different CEST signals in the Z-spectrum is a challenge especially at low field strengths where amide, amine, and NOE peaks coalesce with each other or with…

physics.med-ph2013★ 2 cited

Inverse Z-spectrum analysis for MT- and spillover-corrected and T1-compensated steady-state pulsed CEST-MRI - application to pH-weighted MRI of acute stroke

Moritz Zaiss, Junzhong Xu, Steffen Goerke +5

Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects such as direct water proton saturation (spillover) and macromolecular magnet…

physics.med-ph2012★ 221 cited

Exchange-dependent relaxation in the rotating frame for slow and intermediate exchange - modeling off-resonant spin-lock and chemical exchange saturation transfer

Moritz Zaiss, Peter Bachert

Chemical exchange observed by NMR saturation transfer (CEST) and spin-lock (SL) experiments provide an MRI contrast by indirect detection of exchanging protons. The determination o…