7 citations · 30 across the 10 of their papers we have counts for
11 papers · 1 filter
Performance of the High-Angle Time Projection Chambers in the Upgraded T2K Off-Axis Near Detector
K. Aivazelis, D. Attié, P. Billoir +94
The off-axis magnetic near detector of the T2K experiment has undergone a significant upgrade, including the construction and installation of two new Time Projection Chambers featu…
Embedding the Timepix4 in Micro-Pattern Gaseous Detectors
L. Scharenberg, J. Alozy, W. Billereau +27
The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous…
Towards MPGDs with embedded pixel ASICs
L. Scharenberg, J. Alozy, W. Billereau +27
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution…
Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X-Y-U)-strip anode readout
Kondo Gnanvo, Andrew Weisenberger, Seung Joon +3
The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X-Y-U)-strip r…
FAT-GEMs: (Field Assisted) Transparent Gaseous-Electroluminescence Multipliers
S. Leardini, A. Sáa-Hernández, M. Kuźniak +12
The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a techn…
Characterisation of resistive MPGDs with 2D readout
L. Scharenberg, F. Brunbauer, H. Danielson +22
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out w…
Time Projection Chamber for GADGET II
Ruchi Mahajan, T. Wheeler, E. Pollacco +17
Background: The established GADGET detection system, designed for measuring weak, low-energy -delayed proton decays, features a gaseous Proton Detector with MICROMEGAS readout f…
Characterization of Charge Spreading and Gain of Encapsulated Resistive Micromegas Detectors for the Upgrade of the T2K Near Detector Time Projection Chambers
D. Attie, O. Ballester, M. Batkiewicz-Kwasnia +92
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, e…
The MAPS foil
S. Beolé, F. Carnesecchi, G. Contin +14
We present a method of embedding a Monolithic Active Pixel Sensor (MAPS) into a flexible printed circuit board (FPC) and its interconnection by means of through-hole copper plating…
A new amplification structure for time projection chambers based on electroluminescence
D. González-Díaz, M. Fontaíña, D. García Castro +6
A simple hole-type secondary scintillation structure (2 mm-hole, 5 mm-pitch, 5 mm-thickness) is introduced and its operation demonstrated in pure xenon in the pressure range 2-10 b…
A study in using MICROMEGAS to improve particle identification with the TAMU-MDM focal plane detector
Alexandra Spiridon, Emmanuel Pollacco, Antti Saastamoinen +5
A MICROMEGAS detection amplifier has been incorporated into the design of the TAMU MDM focal plane detector with the purpose of improving the energy resolution and thus, the partic…