activity
19992026
most citedBranching ratios and spectral functions of tau decays: final ALEPH measurements and physics implications

351 citations · 1.5k across the 49 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

24 papers · 1 filter

physics.ins-det2024

Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider

Antonello Pellecchia, Marco Buonsante, Maryna Borysova +14

Micro-pattern gaseous detectors (MPGDs) are a promising readout technology for hadronic calorimeters (HCAL) thanks to their good space resolution, longevity and rate capability. We…

physics.ins-det2023★ 2 cited

Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer

Inseok Yoon

The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited suppl…

physics.ins-det2022

Report of the Topical Group on Micro-Pattern Gaseous Detectors for Snowmass 2021

B. Surrow, M. Titov, S. Vahsen +10

This report summarizes white papers on micro-pattern gaseous detectors (MPGDs) that were submitted to the Instrumentation Frontier Topical Group IF05, as part of the Snowmass 2021…

physics.ins-det2022★ 26 cited

Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

M. Abbas, M. Abbrescia, H. Abdalla +179

The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS…

physics.ins-det2022★ 4 cited

Promising Technologies and R&D Directions for the Future Muon Collider Detectors

Sergo Jindariani, Federico Meloni, Nadia Pastrone +58

Among the post-LHC generation of particle accelerators, the muon collider represents a unique machine with capability to provide very high energy leptonic collisions and to open th…

physics.ins-det2022★ 1 cited

MPGDs for tracking and Muon detection at future high energy physics colliders

K. Black, A. Colaleo, C. Aimè +61

In the next years, the energy and intensity frontiers of the experimental Particle Physics will be pushed forward with the upgrade of existing accelerators (LHC at CERN) and the en…

physics.ins-det2021★ 1 cited

Modeling the triple-GEM detector response to background particles for the CMS Experiment

M. Abbas, M. Abbrescia, H. Abdalla +186

An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the…

physics.ins-det2021

Performance of a Triple-GEM Demonstrator in Collisions at the CMS Detector

M. Abbas, M. Abbrescia, H. Abdalla +178

After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the…

physics.ins-det2020★ 1 cited

Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

M. Abbas, M. Abbrescia, H. Abdalla +178

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensio…

physics.ins-det2019★ 8 cited

Diamond-Like Carbon for the Fast Timing MPGD

Anna Colaleo, Giuseppe De Robertis, Francesco Licciulli +23

The present generation of Micro-Pattern Gaseous Detectors (MPGDs) are radiation hard detectors, capable of detecting efficiently particle rates of several MHz/cm , while exhibi…

physics.ins-det2015

A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

D. Abbaneo, M. Abbas, M. Abbrescia +153

We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to…

physics.ins-det2015★ 2 cited

Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors

D. Abbaneo, M. Abbas, M. Abbrescia +153

A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and…

physics.ins-det2014★ 3 cited

Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

D. Abbaneo, M. Abbas, M. Abbrescia +134

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for…

physics.ins-det2014★ 3 cited

CMS RPC muon detector performance with 2010-2012 LHC data

G. Pugliese

The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drif…

physics.ins-det2014

Radiation background with the CMS RPCs at the LHC

Silvia Costantini

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of th…

physics.ins-det2013★ 1 cited

Potential Impact of a New GEM-based Detector on CMS Triggering

A. Castaneda

With the increases in the LHC instantaneous luminosity, maintaining effective triggering and avoiding dead time will become especially challenging. As the sensitivity of many physi…

physics.ins-det2013★ 1 cited

Simulation of the CMS Resistive Plate Chambers

R. Hadjiiska, L. Litov, B. Pavlov +61

The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation…

physics.ins-det2012★ 7 cited

A study of gas contaminants and interaction with materials in RPC closed loop systems

S. Colafranceschi, R. Aurilio, L. Benussi +18

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this pape…

physics.ins-det2012★ 11 cited

Uniformity and Stability of the CMS RPC Detector at the LHC

S. Costantini, K. Beernaert, A. Cimmino +60

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of th…

physics.ins-det2012★ 13 cited

The Upgrade of the CMS RPC System during the First LHC Long Shutdown

M. Tytgat, A. Marinov, P. Verwilligen +31

The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon…

physics.ins-det2012★ 12 cited

CMS Resistive Plate Chamber overview, from the present system to the upgrade phase I

P. Paolucci, R. Hadjiiska, L. Litov +60

University of Sofia, Faculty of Physics, Atomic Physics Department, 5, James Bourchier Boulevard, BG-1164 Sofia, Bulgaria Ghent University, Department of Physics and Astronomy, Pro…

physics.ins-det2011★ 17 cited

Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System

M. Tytgat, A. Marinov, N. Zaganidis +56

At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the…

physics.ins-det2011

Test beam results of the GE1/1 prototype for a future upgrade of the CMS high- muon system

D. Abbaneo, M. Abbrescia, C. Armagnaud +55

Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<…

physics.ins-det2008★ 28 cited

The CMS RPC gas gain monitoring system: an overview and preliminary results

L. Benussi, S. Bianco, S. Colafranceschi +40

The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a…