511 citations · 1.1k across the 52 of their papers we have counts for
54 papers
Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment
N. Schermer, H. Abele, G. Angloher +57
The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CENS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this wo…
Optimization studies of silicon remoTES cryogenic calorimeters
G. Angloher, M. R. Bharadwaj, A. Boehmer +42
The remoTES design, developed within the COSINUS experiment, enables a broader range of materials to be operated as cryogenic calorimeters read out with Transition Edge Sensors (TE…
Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
M. Cappelli, A. Wallach, H. Abele +62
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of det…
Cosmic Ray Boosted Dark Matter in COSINUS: Modeling and Constraints
G. Angloher, M. R. Bharadwaj, A. Böhmer +41
Direct detection of nuclear recoils due to sub-GeV dark matter is challenging because of the small kinetic energy of the light dark matter particles. Although limits down to a few…
ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies
G. Angloher, S. Banik, A. Bento +57
We present ImpCresst, a Geant4-based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their…
Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches
H. Abele, G. Angloher, B. Arnold +62
The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CENS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters…
Characterization of the Low Energy Excess using a NUCLEUS AlO detector
H. Abele, G. Angloher, B. Arnold +62
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other…
Defect Formation in NaI Crystals: A Novel Pathway to Dark Matter Detection
G. Angloher, M. R. Bharadwaj, A. Böhmer +44
Sodium iodide (NaI) is a widely used scintillator in direct dark matter searches. In particular, NaI-based cryogenic scintillating calorimeters have emerged as promising candidates…
Observation of two nuclear recoil peaks induced by neutron capture on Al2O3
H. Abele, P. Ajello, B. Arnold +43
We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic AlO detector developed by the NUCLEUS collaboration for the dete…
Quenching factors for Na recoils as a function of Tl dopant concentrations in NaI(Tl) crystals
G. Angloher, M. R. Bharadwaj, A. Böhmer +51
Thallium-doped sodium iodide (NaI(Tl)) scintillation detectors play an important role in the field of direct dark matter (DM) searches. The DAMA/LIBRA experiment stands out for its…
Description of CRESST-III lithium aluminate data
G. Angloher, S. Banik, G. Benato +58
Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set…
Particle background characterization and prediction for the NUCLEUS reactor CENS experiment
H. Abele, G. Anglogher, B. Arnold +57
NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CENS) and to search for new physics at the Chooz nuclear power pl…
Description of CRESST-II and CRESST-III pulse shape data
G. Angloher, S. Banik, D. Bartolot +62
A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data…
Commissioning of the NUCLEUS Experiment at the Technical University of Munich
H. Abele, G. Angloher, B. Arnold +57
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO targets in the fully coherent regime, using gram-scale cryog…
COSINUS -- a model-independent challenge of the DAMA/LIBRA dark matter claim with cryogenic NaI detectors operated in a new low-background facility
G. Angloher, M. R. Bharadwaj, A. Böhmer +40
Low-temperature detectors are a powerful technology for dark matter search, offering excellent energy resolution and low energy thresholds. COSINUS is the only experiment that comb…
Observation of a low energy nuclear recoil peak in the neutron calibration data of an AlO crystal in CRESST-III
CRESST Collaboration, G. Angloher, S. Banik +59
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of (10)eV for nucl…
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
H. Abele, P. Ajello, A. Armatol +51
The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interes…
The CRESST experiment: towards the next-generation of sub-GeV direct dark matter detection
G. Angloher, S. Banik, A. Bento +54
Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model…
Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source
H. Abele, G. Angloher, B. Arnold +61
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on…
COSINUS model-independent sensitivity to the DAMA/LIBRA dark matter signal
G. Angloher, M. R. Bharadwaj, A. Böhmer +40
COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scatt…
Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures
The NUCLEUS collaboration, A. Wex, J. Rothe +64
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems…
Neutrino flux sensitivity to the next galactic core-collapse supernova in COSINUS
G. Angloher, M. R. Bharadwaj, M. Cababie +39
While neutrinos are often treated as a background for many dark matter experiments, these particles offer a new avenue for physics: the detection of core-collapse supernovae. Super…
Constraints on self-interaction cross-sections of dark matter in universal bound states from direct detection
The CRESST Collaboration
Lambda- Cold Dark Matter (LambdaCDM) has been successful at explaining the large-scale structures in the universe but faces severe issues on smaller scales when compared to observa…
Water Cherenkov muon veto for the COSINUS experiment: design and simulation optimization
G. Angloher, M. R. Bharadwaj, M. Cababie +36
COSINUS is a dark matter (DM) direct search experiment that uses sodium iodide (NaI) crystals as cryogenic calorimeters. Thanks to the low nuclear recoil energy threshold and event…