activity
20162025
most citedPICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector

87 citations · 152 across the 10 of their papers we have counts for

collaborators

11 papers

physics.ins-det2025

Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector

Djunes Janssens, Antonija Utrobicic, Marinko Kovacic +52

The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a…

physics.ins-det2023★ 1 cited

A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution

Antonija Utrobicic, Yannis Angelis, Stephan Aune +42

The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof…

physics.ins-det2023★ 13 cited

Towards robust PICOSEC Micromegas precise timing detectors

Marta Lisowska, Yannis Angelis, Stephan Aune +43

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-chann…

physics.class-ph2022★ 8 cited

The Excited State Dynamics of a Mutagenic Cytidine Etheno Adduct Investigated by Combining Time-Resolved Spectroscopy and Quantum Mechanical Calculations

Paloma Lizondo-Aranda, Lara Martínez-Fernández, Miguel Miranda +3

Joint femtosecond fluorescence upconversion experiments and theoretical calculations provide a hitherto unattained degree of characterization and understanding of the mutagenic eth…

physics.ins-det2021★ 14 cited

Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

S. Aune, J. Bortfeldt, F. Brunbauer +39

The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a…

physics.ins-det2019★ 22 cited

Timing Performance of a Micro-Channel-Plate Photomultiplier Tube

Jonathan Bortfeldt, Florian Brunbauer, Claude David +36

The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position informatio…

physics.ins-det2019★ 4 cited

Precise Charged Particle Timing with the PICOSEC Detector

J. Bortfeldt, F. Brunbauer, C. David +38

The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabili…

physics.ins-det2019★ 1 cited

Modeling the Timing Characteristics of the PICOSEC Micromegas Detector

J. Bortfeldt, F. Brunbauer, C. David +38

The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also dem…

physics.ins-det2018★ 2 cited

Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept

F. J. Iguaz, J. Bortfeldt, F. Brunbauer +38

The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been te…

physics.ins-det2017★ 87 cited

PICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector

J. Bortfeldt, F. Brunbauer, C. David +37

The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accura…

physics.ins-det2016

Fast Timing for High-Rate Environments with Micromegas

Thomas Papaevangelou, Daniel Desforge, Esther Ferrer-Ribas +11

The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showe…