activity
20162022
most citedSelf-corrected chip-based dual-comb spectrometer

120 citations · 225 across the 10 of their papers we have counts for

collaborators

10 papers

physics.optics2022

Linear detection of 30 mW dual-comb interferograms

Philippe Guay, Mathieu Walsh, Alex Tourigny-Plante +1

Detector nonlinearity is an important factor limiting the maximal power and hence the signal-to-noise ratio (SNR) in dual-comb interferometry. To increase the SNR without overwhelm…

physics.optics2022

Addressing asymmetric Fano profiles on molecular lines in dual-comb spectroscopy

Philippe Guay, Mathieu Walsh, Jérôme Genest

Fano resonance in molecular spectroscopy is reported with a dual-comb instrument. The effect is observed as asymmetric absorption lines of H12CN. Pulse chirping conditions in the g…

physics.ins-det2021★ 14 cited

Correcting photodetector nonlinearity in dual-comb interferometry

Philippe Guay, Nicolas Bourbeau Hébert, Alex Tourigny-Plante +2

Photodetector nonlinearity, the main limiting factor in terms of optical power in the detection chain, is corrected to improve the signal-to-noise ratio of a short-time measurement…

physics.optics2021

Understanding photodetector nonlinearity in dual-comb interferometry

Philippe Guay, Alex Tourigny-Plante, Vincent Michaud-Belleau +3

The impact of photodetector nonlinearity on dual-comb spectrometers is described and compared to that of Michelson-based Fourier transform spectrometers (FTS). The optical sampling…

physics.ins-det2021★ 5 cited

Balanced photodetectors nonlinearity for short-pulse regime

Philippe Guay, Jérôme Genest

Short pulse lasers are used to characterize the nonlinear response of amplified photodetectors. Two widely used balanced detectors are characterized in terms of amplitude, area, br…

physics.optics2019

Single-frequency mid-infrared chip laser with a sub-hertz Lorentzian linewidth

Philippe Guay, Jérôme Genest, Vincent Michaud-Belleau +2

A guided-wave chip laser operating in a single longitudinal mode at 2860 nm is presented. The cavity was set in the Littman-Metcalf configuration to achieve single-frequency operat…

physics.optics2019★ 1 cited

Amplified noise nonstationarity in a mode-locked laser based on nonlinear polarization rotation

Carlos Andres Perilla Rozo, Philippe Guay, Jean-Daniel Deschênes +1

Beat note measurements between a mode-locked and a continuous-wave laser as well as between two mode-locked sources were used to demonstrate that the sub-threshold, cavity filtered…

eess.SP2018★ 54 cited

An open and flexible digital phase-locked loop for optical metrology

Alex Tourigny-Plante, Vincent Michaud-Belleau, Nicolas Bourbeau-Hébert +3

This paper presents an open and flexible digital phase lock loop optimized for laser stabilization systems. It is implemented on a cheap and easily accessible FPGA-based digital el…

physics.optics2017★ 120 cited

Self-corrected chip-based dual-comb spectrometer

Nicolas Bourbeau Hébert, Jérôme Genest, Jean-Daniel Deschênes +4

We present a dual-comb spectrometer based on two passively mode-locked waveguide lasers integrated in a single Er-doped ZBLAN chip. This original design yields two free-running fre…

physics.optics2016★ 31 cited

Ultrafast pulse generation in a mode-locked Erbium chip waveguide laser

Champak Khurmi, Nicolas Bourbeau Hébert, Wen Qi Zhang +5

We report mode-locked ~1550 nm output of transform-limited ~180 fs pulses from a large mode-area (diameter ~ 50 μm) guided-wave erbium fluorozirconate glass laser. The passively mo…