94 citations · 579 across the 23 of their papers we have counts for
9 papers · 1 filter
Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer
Inseok Yoon
The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited suppl…
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
M. Abbas, M. Abbrescia, H. Abdalla +179
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS…
Modeling the triple-GEM detector response to background particles for the CMS Experiment
M. Abbas, M. Abbrescia, H. Abdalla +186
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the…
Performance of a Triple-GEM Demonstrator in Collisions at the CMS Detector
M. Abbas, M. Abbrescia, H. Abdalla +178
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the…
A new technique to establish the uniformity of the induction gap in GEM based detector
Mohit Gola
This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the in…
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
M. Abbas, M. Abbrescia, H. Abdalla +178
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensio…
Stability tests performed on the triple GEM detector built using commercially manufactured GEM foils in India
Mohit Gola, Shivali Malhotra, Ashok Kumar +1
The Gas Electron Multiplier (GEM) technology is based on thin polymer foils cladded with copper on both the sides with a regular matrix of holes. Due to the limited manufacturing c…
Performance of the triple GEM detector built using commercially manufactured GEM foils in India
Mohit Gola, Aashaq Shah, Asar Ahmed +3
The Gas Electron Multiplier (GEM) detectors has been utilized for various applications due to their excellent spatial resolution, high rate capabilities and flexibility in design.…
Development, Characterization and Qualification of first GEM foils produced in India
Aashaq Shah, Asar Ahmed, Mohit Gola +6
The increasing demand for Gas Electron Multiplier (GEM) foils has been driven by their application in many current and proposed high-energy physics experiments. Micropack, a Bengal…