129 citations · 1k across the 45 of their papers we have counts for
18 papers · 1 filter
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
Didier Barret, Vincent Albouys, Jan-Willem den Herder +296
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile ob…
Geant4 simulation of the residual background in the ATHENA Wide Field Imager from protons deflected by the Charged Particle Diverter
Gábor Galgóczi, Jean-Paul Breuer, Valentina Fioretti +11
X-ray telescopes opened up a new window into the high-energy universe. However, the last generation of these telescopes encountered an unexpected problem: their optics focused not…
Athena charged particle diverter simulations: effects of micro-roughness on proton scattering using Geant4
Jean-Paul Breuer, Gábor Galgóczi, Valentina Fioretti +12
The last generation of X-ray focusing telescopes operating outside the Earth's radiation belt discovered that optics were able to focus not only astrophysical X-ray photons, but al…
Scattering efficiencies measurements of soft protons at grazing incidence from an Athena Silicon Pore Optics sample
R. Amato, S. Diebold, A. Guzman +4
Soft protons are a potential threat for X-ray missions using grazing incidence optics, as once focused onto the detectors they can contribute to increase the background and possibl…
Effective pointing of the ASTRI-Horn telescope using the Cherenkov camera with the Variance method
Simone Iovenitti, Giorgia Sironi, Alberto Segreto +2
Cherenkov telescope cameras are not suitable to perform astrometrical pointing calibration since they are not designed to produce images of the sky, but rather to detect nanosecond…
Soft proton scattering at grazing incidence from X-ray mirrors: analysis of experimental data in the framework of the non-elastic approximation
R. Amato, T. Mineo, A. D'Aì +9
Astronomical X-ray observatories with grazing incidence optics face the problem of pseudo-focusing of low energy protons from the mirrors towards the focal plane. Those protons con…
Calibration and monitoring of the ASTRI-Horn telescope by using the night-sky background measured by the photon-statistics ("variance") method
A. Segreto, O. Catalano, M. C. Maccarone +2
ASTRI-Horn is the Cherenkov telescope developed by INAF and operating in Italy on the slopes of Etna volcano. Characterized by a dual-mirror optical system and a focal plane covere…
Muon calibration of the ASTRI-Horn telescope: preliminary results
T. Mineo, M. C. Maccarone, A. Compagnino +8
Astri-Horn is a Small-Sized Telescope (SST) for very-high energy gamma-ray astronomy installed in Italy at the INAF "M.C. Fracastoro" observing station (Mt. Etna, Sicily). The ASTR…
Using Muon Rings for the Optical Throughput Calibration of the Cherenkov Telescope Array
Markus Gaug, Stephen Fegan, Alison Mitchell +3
Muon ring images observed with Imaging Atmospheric Cherenkov Telescopes (IACTs) provide a powerful means to calibrate the optical throughput of IACTs and monitor their optical poin…
Magnetic shielding of soft protons in future X-ray telescopes: the case of the ATHENA Wide Field Imager
Valentina Fioretti, Andrea Bulgarelli, Silvano Molendi +10
Both the interplanetary space and the Earth magnetosphere are populated by low energy ( keV) protons that are potentially able to scatter on the reflecting surface of Wolt…
The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect on soft proton scattering
Valentina Fioretti, Andrea Bulgarelli, Simone Lotti +6
Given the unprecedented effective area, the new ATHENA Silicon Pore Optics (SPO) focusing technology, the dynamic and variable L2 environment, where no X-ray mission has flown up t…
Geant4 simulations of soft proton scattering in X-ray optics. A tentative validation using laboratory measurements
Valentina Fioretti, Teresa Mineo, Andrea Bulgarelli +6
Low energy protons (< 300 keV) can enter the field of view of X-ray space telescopes, scatter at small incident angles, and deposit energy on the detector, causing intense backgrou…
The particle background of the X-IFU instrument
Simone Lotti, Teresa Mineo, Christian Jacquey +4
In this paper we are going to review the latest estimates for the particle background expected on the X-IFU instrument onboard of the ATHENA mission. The particle background is ind…
Effects of capillary reflection in the performance of the collimator of the Large Area Detector on board LOFT
T. Mineo, G. W. Fraser, A. Martindale +4
The Large Observatory For X-ray Timing (LOFT) is one of the candidate missions selected by the European Space Agency for an initial assessment phase in the Cosmic Vision programme.…
Calibration of the ASTRI SST-2M Prototype using Muon Ring Images
Elisabetta Strazzeri, Giacomo Bonnoli, Saverio Lombardi +2
The study of ring images generated from high-energy muons is a very useful tool for the performance monitoring and calibration of any Imaging Atmosphere Cherenkov Telescope. Isolat…
The ASTRI SST-2M Prototype: Camera and Electronics
Osvaldo Catalano, Salvo Giarrusso, Giovanni La Rosa +15
ASTRI is a Flagship Project financed by the Italian Ministry of Education, University and Research, and led by INAF, the Italian National Institute of Astrophysics. The primary goa…
Background simulations for the Large Area Detector onboard LOFT
R. Campana, M. Feroci, E. Del Monte +3
The Large Observatory For X-ray Timing (LOFT), currently in an assessment phase in the framework the ESA M3 Cosmic Vision programme, is an innovative medium-class mission specifica…
LOFT: the Large Observatory For X-ray Timing
M. Feroci, J. W. den Herder, E. Bozzo +245
The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is curren…