16 citations · 70 across the 10 of their papers we have counts for
10 papers
Spill ripple mitigation by bunched beam extraction with high frequency synchrotron motion
Stefan Sorge, Peter Forck, Rahul Singh
Slow extraction of bunched beams is widely used for mitigating the formation of micro structures due to ripples of the accelerator magnets power supplies on the extracted beam whic…
Machine and People Protection
Peter Forck
This contribution acts as an introduction to the requirements of the machine protection system. As the first step, the basics interactions of fast charged particles, neutrons and $…
Beam Instrumentation and Diagnostics
Peter Forck
The determination of beam parameters is essential for the operation and development of any accelerator facility. The working principle of frequently used beam instruments for elect…
Performance of closed orbit feedback systems with spatial model mismatch
Sajjad Hussain Mirza, Rahul Singh, Peter Forck +1
Closed orbit feedback (COFB) systems used for the global orbit correction rely on the pseudo-inversion of the orbit response matrix (ORM). A mismatch between the model ORM used in…
Smoothing of the slowly extracted coasting beam from a synchrotron
Rahul Singh, Peter Forck, Stefan Sorge
Slow extraction of beam from synchrotrons or storage rings as required by many fixed target experiments is performed by controlled excitation and feeding of a structural lattice re…
Closed orbit correction at synchrotrons for symmetric and near-symmetric lattices
Sajjad Hussain Mirza, Rahul Singh, Peter Forck +1
This contribution compiles the benefits of lattice symmetry in the context of closed orbit correction. A symmetric arrangement of BPMs and correctors results in structured orbit re…
Interpretation of transverse tune spectra in a heavy-ion synchrotron at high intensities
R. Singh, O. Boine-Frankenheim, O. Chorniy +6
Two different tune measurement systems have been installed in the GSI heavy-ion synchrotron SIS-18. Tune spectra are obtained with high accuracy using these fast and sensitive syst…
Commissioning of Ih-RFQ and Ih-DTL for the Gsi High Current Linac
W. Barth, P. Forck, J. Glatz +8
The new 1.4 MeV/u front end HSI (HochStromInjektor) of the Unilac accelerates ions with A/q ratios of up to 65 and with beam intensities in emA of up to 0.25 A/q. The maximum beam…
Measurement of the six Dimensional Phase Space at the New GSI High Current Linac
P. Forck, F. Heymach, T. Hoffmann +2
For the characterization of the 10 mA ion beam delivered by the new High Current Linac at GSI, sophisticated, mainly non-intersepting diagnostic devices were developed. Besides the…
The New Gas Stripper and Charge State Separator of the Gsi High Current Injector
W. Barth, P. Forck
The GSI Unilac was upgraded as a high current injector for the SIS in 1999. Therefore, the stripping section [1] at 1.4 MeV/u, where a beam transport under highest space charge con…