168 citations · 411 across the 16 of their papers we have counts for
12 papers · 1 filter
A large area, high counting rate micromegas-based neutron detector for BNCT
Zhujun Fang, Zhiyong Zhang, Bin Shi +11
Beam monitoring and evaluation are very important to boron neutron capture therapy (BNCT), and a variety of detectors have been developed for these applications. However, most of t…
A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution
Antonija Utrobicic, Yannis Angelis, Stephan Aune +42
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof…
Towards robust PICOSEC Micromegas precise timing detectors
Marta Lisowska, Yannis Angelis, Stephan Aune +43
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-chann…
A Light Yield Enhancement Method Using Wavelength Shifter for the STCF EMC
Zekun Jia, Hanlin Yu, Hongkun Mo +5
Super Tau-Charm Facility (STCF) is a next-generation high luminosity electron-positron collider facility and is currently one of the major options for accelerator-based particle ph…
Study of Hybrid MicroPattern Gas Detector with CsI Photocathode For Super Tau-Charm Factory RICH
Ping Li, Qian Liu, Jianbei Liu +7
Super tau-Charm facility(STCF) is a future electron-position collider operating at tau-Charm energy region aimed to study hadron structure and spectroscopy. The baseline design of…
Optimization study of scintillator shape of electromagnetic calorimeter for Higgs factories
Takanori Mogi, Tomohiko Tanabe, Wataru Ootani +5
Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uni…
A thermal bonding method for manufacturing Micromegas detectors
Jianxin Feng, Zhiyong Zhang, Jianbei Liu +4
For manufacturing Micromegas detectors, the "bulk" method based on photoetching, was successfully developed and widely used in nuclear and particle physics experiments. However, th…
Timing Performance of a Micro-Channel-Plate Photomultiplier Tube
Jonathan Bortfeldt, Florian Brunbauer, Claude David +36
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position informatio…
Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector
Binbin Qi, Yang Li, Danyang Zhu +83
The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurement…
Readout Electronics for CEPC Semi-Digital Hadron Calorimeter Pre-prototype
Yu Wang, Shubin Liu, Changqing Feng +5
CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory.…
PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure Xe Gas Time Projection Chambers
Xun Chen, Changbo Fu, Javier Galan +67
Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masse…
A Large area GEM Detector Using an improved Self-stretch Technique
Wenhao You, Yi Zhou, Cheng Li +5
A GEM detector with an effective area of 30*30 cm2 has been constructed using an improved self-stretch technique, which enables an easy and fast GEM assembling. The design and asse…