activity
19952021
most citedTest of CPT Symmetry and Quantum Mechanics with Experimental data from CPLEAR

102 citations · 404 across the 19 of their papers we have counts for

collaborators

19 papers

physics.med-ph2021★ 2 cited

Lesion characterization in spectral photon-counting tomosynthesis

Bjorn Cederstrom, Erik Fredenberg, Karl Berggren +3

It has previously been shown that 2D spectral mammography can be used to discriminate between (likely benign) cystic and (potentially malignant) solid lesions in order to reduce un…

physics.med-ph2021★ 1 cited

Rayleigh imaging in spectral mammography

Karl Berggren, Mats Danielsson, Erik Fredenberg

Spectral imaging is the acquisition of multiple images of an object at different energy spectra. In mammography, dual-energy imaging (spectral imaging with two energy levels) has b…

physics.med-ph2021★ 3 cited

Photon-counting spectral phase-contrast mammography

E. Fredenberg, E. Roessl, T. Koehler +10

Phase-contrast imaging is an emerging technology that may increase the signal-difference-to-noise ratio in medical imaging. One of the most promising phase-contrast techniques is T…

physics.med-ph2021★ 19 cited

Optimization of mammography with respect to anatomical noise

Erik Fredenberg, Bjorn Svensson, Mats Danielsson +2

Beam quality optimization in mammography traditionally considers detection of a target obscured by quantum noise on a homogenous background. It can be argued that this scheme does…

physics.med-ph2021★ 15 cited

Observer model optimization of a spectral mammography system

Erik Fredenberg, Magnus Aslund, Bjorn Cederstrom +2

Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. Contrast…

physics.ins-det2021★ 17 cited

Photon-counting CT with silicon detectors: feasibility for pediatric imaging

Moa Yveborg, Cheng Xu, Erik Fredenberg +1

X-ray detectors made of crystalline silicon have several advantages including low dark currents, fast charge collection and high energy resolution. For high-energy x-rays, however,…

physics.med-ph2021★ 16 cited

A photon-counting detector for dual-energy breast tomosynthesis

Erik Fredenberg, Mats Lundqvist, Magnus Aslund +3

We present the first evaluation of a recently developed silicon-strip detector for photon-counting dual-energy breast tomosynthesis. The detector is well suited for tomosynthesis w…

physics.med-ph2021★ 1 cited

Contrast-enhanced dual-energy subtraction imaging using electronic spectrum-splitting and multi-prism x-ray lenses

Erik Fredenberg, Bjorn Cederstrom, Mats Lundqvist +5

Dual-energy subtraction imaging (DES) is a method to improve the detectability of contrast agents over a lumpy background. Two images, acquired at x-ray energies above and below an…

physics.med-ph2021

Prism-array lenses for energy filtering in medical x-ray imaging

Erik Fredenberg, Bjorn Cederstrom, Carolina Ribbing +1

Conventional energy filters for x-ray imaging are based on absorbing materials which attenuate low energy photons, sometimes combined with an absorption edge, thus also discriminat…

physics.ins-det2021★ 99 cited

Energy resolution of a photon-counting silicon strip detector

Erik Fredenberg, Mats Lundqvist, Bjorn Cederstrom +2

A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinic…

physics.med-ph2021★ 3 cited

An efficient pre-object collimator based on an x-ray lens

Erik Fredenberg, Bjorn Cederstrom, Magnus Aslund +2

A multi-prism lens (MPL) is a refractive x-ray lens with one-dimensional focusing properties. If used as a pre-object collimator in a scanning system for medical x-ray imaging, it…

physics.med-ph2021★ 90 cited

Contrast-enhanced spectral mammography with a photon-counting detector

Erik Fredenberg, Magnus Hemmendorff, Bjorn Cederstrom +2

Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation.…

physics.med-ph2021

Energy filtering with X-ray lenses: optimization for photon-counting mammography

Erik Fredenberg, Bjorn Cederstrom, Mats Danielsson

Chromatic properties of the multi-prism and prism-array X-ray lenses (MPL and PAL) can potentially be utilized for efficient energy filtering and dose reduction in mammography. The…

physics.med-ph2021★ 20 cited

Measurement of breast-tissue x-ray attenuation by spectral mammography: solid lesions

Erik Fredenberg, Fleur Kilburn-Toppin, Paula Willsher +5

Knowledge of x-ray attenuation is essential for developing and evaluating x-ray imaging technologies. For instance, techniques to distinguish between cysts and solid tumours at mam…

astro-ph.IM2020★ 7 cited

A stacked prism lens concept for next generation hard X-ray telescopes

Wujun Mi, Peter Nilius, Mark Pearce +1

Effective collecting area, angular resolution, field of view and energy response are fundamental attributes of X-ray telescopes. The performance of state-of-the-art telescopes is c…

physics.med-ph2018

Robustness of Optimal Energy Thresholds in Photon-counting Spectral CT

Yifan Zheng, Moa Yveborg, Fredrik Grönberg +4

An important question when developing photon-counting detectors for computed tomography is how to select energy thresholds. In this work thresholds are optimized by maximizing sign…

physics.ins-det2004★ 6 cited

Study of capillary-based gaseous detectors

C. Iacobaeus, T. Francke, M. Danielsson +2

We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary…

physics.ins-det2001★ 3 cited

Fundamentals of Gas Micropattern Detectors

V. Peskov, P. Fonte, M. Danielsson +3

We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done…

hep-ex1995★ 102 cited

Test of CPT Symmetry and Quantum Mechanics with Experimental data from CPLEAR

R. Adler, etal, J. Ellis +3

We use fits to recent published CPLEAR data on neutral kaon decays to and to constrain the CPT--violation parameters appearing in a formulation of the neutral kaon s…