308 citations · 517 across the 21 of their papers we have counts for
13 papers · 1 filter
Enhancing Particle Identification in Helium-Based Drift Chambers Using Cluster Counting Insights from Beam Test Studies
W. Elmetenawee, M. Abbrescia, M. Anwar +21
Particle identification in gaseous detectors traditionally relies on energy loss measurements (dE/dx); however, uncertainties in total energy deposition limit its resolution. The c…
Performances of a new generation tracking detector: the MEG II cylindrical drfit chamber
A. M. Baldini, H. Benmansour, G. Boca +28
The cylindrical drift chamber is the most innovative part of the MEG~II detector, the upgraded version of the MEG experiment. The MEG~II chamber differs from the MEG one because it…
Operation and performance of MEG II detector
MEG II Collaboration, K. Afanaciev, A. M. Baldini +82
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully…
The Tracking performance for the IDEA drift chamber
Walaa Elmetenawee, gianluigi chiarello, Alessandro Corvaglia +10
The IDEA detector concept for a future ee collider adopts an ultra-low mass drift chamber as a central tracking system. The He-based ultra-low mass drift chamber is des…
The measuring systems of the wire tension for the MEG II Drift Chamber by means of the resonant frequency technique
A. M. Baldini, H. Benmansour, G. Cavoto +24
The ultra-low mass cylindrical drift chamber designed for the MEG II experiment is a challenging apparatus made of 1728 phi = 20 micron gold plated tungsten sense wires, 7680 phi =…
A photogrammetric method for target monitoring inside the MEG II detector
G. Cavoto, G. Chiarello, M. Hildebrandt +7
An automatic target monitoring method based on photographs taken by a CMOS photo-camera has been developed for the MEG II detector. The technique could be adapted for other fixed-t…
A 10-3 drift velocity monitoring chamber
F. Cuna, G. Chiarello, A. Corvaglia +7
The MEG-II experiment searches for the lepton flavor violating decay: mu in electron and gamma. The reconstruction of the positron trajectory uses a cylindrical drift chamber opera…
The Drift Chamber of the MEG II experiment
G. F. Tassielli, A. M. Baldini, G. Cavoto +19
The MEG experiment at the Paul Scherrer Institut searches for the charged-Lepton-Flavor-Violating mu+ -> e+ gamma decay. MEG has already set the world best upper limit on the branc…
Commissioning of the MEG II tracker system
M. Chiappini, A. M. Baldini, G. Cavoto +19
The MEG experiment at the Paul Scherrer Institut (PSI) represents the state of the art in the search for the charged Lepton Flavour Violating (cLFV) decay.…
The new drift chamber of the MEG II experiment
M. Chiappini, A. M. Baldini, G. Cavoto +15
This article presents the MEG II Cylindrical Drift CHamber (CDCH), a key detector for the phase 2 of MEG, which aims at reaching a sensitivity level of the order of $6 \times 10^{-…
Gas Distribution and Monitoring for the Drift Chamber of the MEG-II Experiment
A. M. Baldini, E. Baracchini, G. Cavoto +22
The reconstruction of the positron trajectory in the MEG-II experiment searching for the decay uses a cylindrical drift chamber operated with a helium-isobutane gas…
The design of the MEG II experiment
A. M. Baldini, E. Baracchini, C. Bemporad +72
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the e…
Single-hit resolution measurement with MEG II drift chamber prototypes
A. M. Baldini, E. Baracchini, G. Cavoto +21
Drift chambers operated with helium-based gas mixtures represent a common solution for tracking charged particles keeping the material budget in the sensitive volume to a minimum.…